background image

26   www.i-sens.com

www.i-sens.com  27

Step 7

 

If you want to attach a post-meal flag ( ) to a 

test result, press and hold the 

 button for 3 

seconds after inserting the test strip. 

The post-meal flag ( ) and the   symbol will 

appear on the screen. If the talking function is 

on, the meter will say "Post-meal test. Please 

apply blood onto the test strip."  The test 

result will also be displayed with the post-

meal flag ( ).
If you do not want to save the result as a post-meal test, move 

on to Step 8 after Step 6. If you want to delete the post-meal 

flag ( ) that you attached, press and hold the 

 button for 3 

seconds again before applying the blood sample or when the 

test result is displayed just after testing.

Flagging Post-meal Test Results

 

CareSens N Voice Meter allows you to flag a result of a post-

meal test with   symbol. The post-meal flag ( ) can be 

attached and deleted just before applying the blood sample 

or when the test result is displayed just after testing. Once the 

test result is saved with the post-meal flag ( ), it cannot be 

deleted.

Step 9

 

After the   symbol appears on the 

screen, apply the blood sample to 

the narrow end of the test strip until 

the meter beeps. If the blood sample 

does not fill the confirmation window 

completely, an Er4 message may 

appear because of abnormal viscosity 

or insufficient volume. If the talking 

function is on, the meter will say "Error 

four. The sample was not enough or too 

thick."  
Then discard the test strip, insert a new 

one, and apply the  blood sample again 

after   symbol appears on the screen. 

Step 8

 

Obtain a blood sample using the lancing 

device. Place the device against the 

pad of the finger. The best puncture 

sites are on the middle or ring fingers. 

Press the release button. Remove the 

lancing device from the finger. Wait 

a few seconds for a blood drop to form. 

A minimum volume of 0.5 microliter is needed to fill the 

confirmation window.

Applying the Blood Sample

Good 

Sample

Insufficient 

Sample

Approximate size

Содержание CareSens N Voice

Страница 1: ...r s lo Sistema de Monitoreo de Glucosa en Sangre Manual del Usuario Funci n de voz L No Codificaci n Segundos For single user home use only Blood Glucose Monitoring System User s Manual No Coding Talk...

Страница 2: ...professional or emergency medical response Bien venido al Sistema de Monitoreo de Glucosa CareSens N Voice Gracias por elegir el Sistema de Monitoreo de Glucosa en Sangre CareSens N Voice El sistema l...

Страница 3: ...d Glucose Testing Using the Lancing Device 23 Preparing the Lancing Device 24 Preparing the Meter and Test Strip 25 Flagging Post meal Test Results 26 Applying the Blood Sample 27 Discarding Used Lanc...

Страница 4: ...rips to check that the meter and the test strips are working together properly and that the test is performing correctly The CareSens N Voice Blood Glucose Monitoring System is intended for in vitro o...

Страница 5: ...N Voice Blood Glucose Meter User s Manual Quick Reference Guide Batteries 2 CareSens N Voice System may include the following items CareSens N Single Blood Glucose Test Strips 10 Lancing Device Lancet...

Страница 6: ...ever you may need to reset your meter settings See page 13 CareSens N Single Blood Glucose Test Strip The CareSens N Voice Blood Glucose Monitoring System measures blood glucose quickly and accurately...

Страница 7: ...er test strips in any way For detailed storage and usage information refer to the CareSens N Single Test Strip package insert Keep the meter and testing supplies away from young children Note You can...

Страница 8: ...date the meter settings such as time and date before using your meter or when you change the meter batteries Press and hold the S button for 3 seconds to enter the SET mode While you are setting the m...

Страница 9: ...ion is on Press or button until blinking number shows the correct date Press the S button to confirm the date and set the time Step 6 Setting the Time Format The meter can be set in the AM PM 12 hour...

Страница 10: ...20 mg dL Step 10 Turning on the Hypoglycemia Indicator When you enter the hypoglycemia indicator setting mode the symbol and HYPo will blink If the talking function is on the meter will say Set hypogl...

Страница 11: ...using the control solution shake the bottle discard the first 1 or 2 drops and wipe the tip clean Close the control solution bottle tightly and store at a temperature of 46 86 F 8 30 C You should do...

Страница 12: ...solution test result by pressing and holding the button for 3 seconds until the ctl appears on the display When the ctl is displayed the result is stored in the meter s memory but is not included in t...

Страница 13: ...ned plus three 3 months When the control solution is contaminated Situations Actions Repeat the control solution test by referring to the Notes on page 18 Discard the used control solution and repeat...

Страница 14: ...h of penetration by rotating the top portion of the adjustable tip until the setting number matches the arrow Step 5 Cock the lancing device by holding the body in one hand and pulling on the sleeve w...

Страница 15: ...ng the blood sample or when the test result is displayed just after testing Once the test result is saved with the post meal flag it cannot be deleted Step 9 After the symbol appears on the screen app...

Страница 16: ...of the symbol appearing on the screen If the meter turns off press S button or button and apply the blood sample after the symbol appears on the screen Step 1 Unscrew the lancing device tip Step 2 Pla...

Страница 17: ...device changes color Then press the release button while continuing to apply pressure Keep holding the lancing device against your skin until sufficient at least 0 5 L blood is drawn Carefully lift t...

Страница 18: ...e to contact with hair or with lines on your palm do not use that sample Try puncturing again in a smoother area Note If messages for hyperglycemia or hypoglycemia are displayed even if you do not hav...

Страница 19: ...isplayed when the data cable connects the meter with computer For more information contact Customer Service at 1 800 429 5001 Meter Memory Step 1 Press the S or button to turn on the meter If the talk...

Страница 20: ...previously To turn off the meter press the S button button button Post meal average 1 7 14 30 90 days button button Pre meal average 1 7 14 30 90 days Step 2 Use the button to scroll through the store...

Страница 21: ...ut symbol being displayed Setting the Alarm Function Setting the Post meal Alarm PP2 alarm Four types of alarms can be set in the CareSens N Voice Meter one post meal alarm PP2 alarm and three time se...

Страница 22: ...d lancing device should be disinfected prior to use by the second person Pre cleaning procedure is needed to clean dirt as well as blood and other body fluids on the exterior of the meter and lancing...

Страница 23: ...the disinfectant product please contact the manufacturer or visit their website as listed above Name Manufacturer EPAregistration number Active ingredients Clorox Germicidal Wipes Clorox Professional...

Страница 24: ...nfectants because other chemicals have not been validated and may damage the meter Do Not get fluids inside the meter through the test strip port data transmission port or battery compartment Never im...

Страница 25: ...n or technical assistance by calling our Customer Service Center 1 800 429 5001 9 am 9 pm EST Monday Saturday Message What is said Error 1 Used test strip Error 2 The sample has been applied before th...

Страница 26: ...Customer Service 1 800 429 5001 9 am 9 pm EST Monday Saturday Message What is said What it means What to do Error 6 Error 7 Error 8 Error 9 Meter failure There is a problem with the meter Do not use t...

Страница 27: ...pm EST Monday Saturday Within 5 Within 10 Within 15 Within 20 54 93 58 82 93 88 93 93 100 93 93 100 Within 5mg dL 14 17 82 17 17 100 17 17 100 Within 10mg dL Within 15mg dL Performance Characteristics...

Страница 28: ...omparison of results using various AST sites with the results of YSI measurements Alternative site test results for glucose concentration 75 mg dL Within 5mg dL Within 10mg dL Within 15mg dL Fingertip...

Страница 29: ...r handling tampering use or service of the meter Any claim must be made within the warranty period The i SENS Inc will at its discretion repair or replace a defective meter or meter part that is cover...

Отзывы: