background image

2

Safety Information

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT 

CAREFULLY.

This appliance is supplied with a moulded three pin mains plug for your 

safety and convenience.

A 5 amp fuse is fitted in this plug.

Should the fuse need to be replaced please ensure that the replacement 

fuse has a rating of 5 amp and that it is approved by ASTA or BSI to 

BS1362.

Check for the ASTA mark 

 or the BSI mark 

 on the body of the 

fuse.

If the plug contains a removable fuse cover you must ensure that it is 

refitted when the fuse is replaced.

If you lose the fuse cover the plug must not be used until a replacement 

cover is obtained.

A replacement fuse cover can be purchased from your local our dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE 

SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE 

REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY.

THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT 

OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.

How to replace the fuse

The location of the differs according to the type of AC mains plug (fig-

ures A and B).

Confirm the AC mains plug fitted and follow the instructions below. 

Illustrations may differ from actual AC mains plug.

Open the fuse cover with a screwdriver and replace the fuse and close 

or attach the fuse cover.

Figure A 

Figure B

For U.K.

Caution:

•  This recorder is only intended for a connection to an ethernet 

or PoE network without routing to the outside plant.

•  This product has no power switch. Be sure to install discon-

nect devices such as a circuit breaker to shut down the main 
power of power supplying equipment to this product.

•  Before attempting to connect or operate this product, please 

read these instructions carefully.

Notice:

•  This product is not suitable for use in locations where children 

are likely to be present.

•  For information about screws and other parts required for 

installation, refer to the corresponding section of this 
document.

•  The power supply cord is used as the main disconnect 

device, ensure that the socket-outlet is located/installed near 
the equipment and is easily accessible.

•  This product is a professional equipment.

:  Functional earthing; functional grounding(US) symbol

: Direct current symbol

: Alternation current symbol

: Polarity of d.c. power connector

: For indoor use only

: Computer network

: Mouse port

: USB port

The model number and serial number of this product may 
be found on the surface of the unit.
You should note the model number and serial number of 
this unit in the space provided and retain this book as a 
permanent record of your purchase to aid identification in 
the event of theft.

  Model No. 

  Serial No.

For U.S.A.

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) 
this device must accept any interference received, 
including interference that may cause undesired operation.

For U.S.A.

Supplier's Declaration of conformity Trade
Name: i-PRO
Model No. : WJ-NU301K
Responsible Party:  i-PRO Americas Inc. 

8550 Fallbrook Drive, Suite 200 
Houston, 
Texas 77064

Support Contact: 1-800-513-5417

For U.S.A.

Note:

 This equipment has been tested and found to 

comply with the limits for a Class A digital device, pursuant 

to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference 

when the equipment is operated in a commercial 

environment. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and 

used in accordance with the instruction manual, may 

cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

FCC Caution:

Changes or modifications not expressly approved by the 

party responsible for compliance could void the user's 

authority to operate the equipment.

For U.S.A.

CAN ICES-3(A)/NMB-3(A)

For Canada

WARNING:

•  All work related to the installation and earthing of this product 

should be made by qualified service personnel or system 
installers.

•  Operation of this product in a residential environment could 

cause radio interference.

Содержание WJ-NU301K Series

Страница 1: ...tions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Important Information Network Disk Recorder Model No WJ NU301K Series For profes...

Страница 2: ...outlet is located installed near the equipment and is easily accessible This product is a professional equipment Functional earthing functional grounding US symbol Direct current symbol Alternation c...

Страница 3: ...red trademarks 6 About HEVC High Efficiency Video Coding patents 6 Copyright 6 Disclaimer of warranty 7 Network security 7 Limitation of liability 7 Precautions 8 Major operating controls and their fu...

Страница 4: ...the camera with an external HDD and USB memory sold separately The copied images can be played printed or saved using the dedicated viewer software Up to 16 cameras can be connected and recorded This...

Страница 5: ...5 Introduction continued System Configuration Main monitor HDMI Sub monitor HDMI PC Network switch Network camera 16 max Network Mouse included...

Страница 6: ...ements OS Microsoft Windows 10 Microsoft Windows 11 Web browser Microsoft Edge Google Chrome Mozilla Firefox CPU Intel CoreTM i7 860 Memory 4 GB or more Monitor 1024 768 pixels or more 24 bit True col...

Страница 7: ...SS FOR ANY PARTICULAR PURPOSE OR NON INFRINGEMENT OF THE THIRD PARTY S RIGHT THIS PUBLICATION COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS CHANGES ARE ADDED TO THE INFORMATION HEREIN A...

Страница 8: ...to observe this may cause electric shock Do not connect disconnect the power plug with wet hands Failure to observe this may cause electric shock Avoid doing anything that can damage the power cord p...

Страница 9: ...while their motors are still running Please be forewarned that any loss of information on the HDD is not guaranteed under any circumstances Do not move or install this product just after turning the...

Страница 10: ...ct for the equipment classification and power source etc About reboot of this product In the following cases this product will automatically reboot to continue recording When the software of this prod...

Страница 11: ...when an alarm occurs and lights when the alarm output stops This indicator will go off when the Reset button Operating Instructions PDF is clicked Recording indicator REC Lights orange when recording...

Страница 12: ...2 0 The included mouse is connected to this port Network port PC port PC Connect the recorder with a PC via a network compatible with 10BASE T 100BASE TX or 1000BASE T The right lamp orange only light...

Страница 13: ...m from the power cord connector to fix it to the clamp mount Cut the excessive part of the cable clamp if necessary How to prevent the Ethernet cable from disconnecting Tighten and secure the bundled...

Страница 14: ...anager 1 High Operator 2 Viewer 3 Logged out 4 Low When the two or more users at the same level perform the same operation the recorder will be controlled in accordance with the latest operation Defau...

Страница 15: ...Hz Mouse connection port High speed serial interface USB2 0 1 Copy port High speed serial interface USB3 0 1 Alarm Control connector Alarm input 1 2 3 and 4 1 Alarm output 2 Emergency recording input...

Страница 16: ...GQP3561ZA i PRO Co Ltd Tokyo Japan https www i pro com Authorised Representative in EU i PRO EMEA B V Laarderhoogtweg 25 1101 EB Amsterdam Netherlands i PRO EMEA B V UK Branch 1010 Cambourne Business...

Отзывы: