Device 

The values are preconfigured and be selected by right-clicking a respective field. 
00: BroadR-Reach Registers access 
1F: RDB Register access 

Register 

Is the PHY Register address relative to the block selected in the Device field. Entering 
a value and pressing ENTER or TAB will read the respective register. 

Value 

Represents a PHY register value that has been read entering the address data in the 
Device and Register fields. Entering a value in this field will result in a write operation 
to the respective register. Written values are read back and displayed for a validation 
of the write operation. 

All entries are expected to be hexadecimal numbers. 

7.3 

TX Functions 

The  “legacy”  Ethernet  PHY  supports  Link  State  Monitoring  and  Register Access  like  the  T1  PHY. 
Please refer to the previous section for a description. 

The used KSZ8081 PHY does not support Clause 45 MDIO addressing or indirect register addressing. 
The Device address is set permanently to 0x00 and can be ignored. 

 

Содержание Factory-Link-SPE-M

Страница 1: ...User Manual Factory Link SPE M Industrial SPE 100BASE T1 Media Converter INO_Factory Link SPE M_User_Manual_V1 0 docx...

Страница 2: ...T1 Cable Recommendation 6 5 2 Power Connector 7 5 2 1 Receptacle Specification 7 5 2 2 Pin Assignment 7 5 2 3 Power Cable Recommendation 7 6 Configuration 8 6 1 T1 Role DIP1 8 6 2 Auto Role Switch DI...

Страница 3: ...INO_Factory Link SPE M_User_Manual_V1 0 docx 2022 09 10 3 12 Revision History Revision Date Change 1 0 05 27 2022 initial release version...

Страница 4: ...ave detection eases the T1 link configuration Master slave role can also be set manually using a DIP switch The wide power supply range from 5V to 28V allows a hassle free installation in various envi...

Страница 5: ...Surge and ESD Protection IEC 61000 4 2 ESD 30 kV Air Contact IEC 61000 4 5 Lightning 45 A 8 20 s USB ESD Protection IEC 61000 4 2 ESD 15 kV Air 8 kV Contact Network Interfaces PHYs 100BASE T1 PHY Broa...

Страница 6: ...500 2812 tbd tbd Terminals Pin Signal Remark 1 Data P 2 Data N SHD Shield Connector Housing Description Manufacturer Structure Jacket Shield AWG T1 SPE IP20 1x2xAWG26 7 PUR 15m Harting 2x0 13mm2 yes y...

Страница 7: ...utor Distributor Number Mating Plug 3Pos Terminal Block Plug 2 5mm 180 free hanging W rth Elektronik 691381030003 Digi Key 732 6056 ND Pin Signal Remark 1 PWR 5V 28V DC 2 GND 3 SHIELD Chassis GND Desc...

Страница 8: ...iation 6 2 Auto Role Switch DIP2 DIP2 controls a proprietary Auto Role Switch function When turned on the Factory Link SPE M automatically determines the T1 link role master or slave This function is...

Страница 9: ...it provides direct access to the register sets of the integrated PHYs It provides the following functions Controller 100BASE T1 connection 100BASE TX connection Media Converter Selection Firmware Info...

Страница 10: ...cs Using the T1 PHY Cable Diagnostics cable faults and their distance from the device can be detected During the measurement the link is broken The distance measurement has a tolerance of 1 5m Cable D...

Страница 11: ...been read entering the address data in the Device and Register fields Entering a value in this field will result in a write operation to the respective register Written values are read back and displa...

Страница 12: ...RoHS Restriction of the use of certain hazardous substances dt Restriction of use certain dangerous substances 8 3 CE Marking The i novative Factory Link SPE M has the CE mark This device complies wi...