background image

 

INO_Factory-Link-SPE-M_User_Manual_V1.0.docx 

 

 

2022-09-10   

 

10 / 12 

 

7.1 

Controller Functions 

If you have attached multiple i-novative

®

 Media Converters to the same host via the USB configuration 

port, you can connect the UI to a specific one using the drop-down list. The Media Converters are 
distinguished by their type and USB serial number. 

When an i-novative

®

 Media Converter is selected, its firmware revision and firmware date are read 

out and displayed in the respective fields. 

Using the RESET button, the Media Converter is re-initialized to its default state. 

 

7.2 

T1 Functions 

Link Monitoring

 

The UI provides continuous monitoring of T1 link state and SQI (Signal Quality Indicator). Using the 
checkboxes, you can enable and disable the respective functions. 

The bars of the SQI bar-graph represent the exact SQI values ranging from SQI=1 to SQI=5. SQI 
needs to be 1 or higher for proper operation of the link. 

Cable Diagnostics

 

Using the T1 PHY Cable Diagnostics, cable faults and their distance from the device can be detected. 
During the measurement, the link is broken. The distance measurement has a tolerance of ±1.5m. 
Cable  Diagnostics  can  detect  broken  wires  (OPEN)  and  intra-pair  shorts  (SHORT).  In  case  of  an 
INVALID result, try to repeat the measurement. PAIR BUSY indicates traffic on the pair. Turn off the 
link partner in order to get a valid result. 

Register Access

 

The Register Table allows to directly read and write PHY registers. Modifying the register settings can 
impact the Media Converter operation. All changes are transient and are lost after resetting or power 
cycling the device. Please use this function only if you do have the required knowledge. The software 
prevents write access to registers which can impact the hardware configuration. For a documentation 
of the PHY registers contact the PHY vendor. 

The Register Table is laid out for Clause 45 MDIO access. Since the integrated BCM89811 PHY does 
not support Clause 45 addressing, the Device address is used here to ease access to registers that 
need a specific access procedure. 

 

 

Содержание Factory-Link-SPE-M

Страница 1: ...User Manual Factory Link SPE M Industrial SPE 100BASE T1 Media Converter INO_Factory Link SPE M_User_Manual_V1 0 docx...

Страница 2: ...T1 Cable Recommendation 6 5 2 Power Connector 7 5 2 1 Receptacle Specification 7 5 2 2 Pin Assignment 7 5 2 3 Power Cable Recommendation 7 6 Configuration 8 6 1 T1 Role DIP1 8 6 2 Auto Role Switch DI...

Страница 3: ...INO_Factory Link SPE M_User_Manual_V1 0 docx 2022 09 10 3 12 Revision History Revision Date Change 1 0 05 27 2022 initial release version...

Страница 4: ...ave detection eases the T1 link configuration Master slave role can also be set manually using a DIP switch The wide power supply range from 5V to 28V allows a hassle free installation in various envi...

Страница 5: ...Surge and ESD Protection IEC 61000 4 2 ESD 30 kV Air Contact IEC 61000 4 5 Lightning 45 A 8 20 s USB ESD Protection IEC 61000 4 2 ESD 15 kV Air 8 kV Contact Network Interfaces PHYs 100BASE T1 PHY Broa...

Страница 6: ...500 2812 tbd tbd Terminals Pin Signal Remark 1 Data P 2 Data N SHD Shield Connector Housing Description Manufacturer Structure Jacket Shield AWG T1 SPE IP20 1x2xAWG26 7 PUR 15m Harting 2x0 13mm2 yes y...

Страница 7: ...utor Distributor Number Mating Plug 3Pos Terminal Block Plug 2 5mm 180 free hanging W rth Elektronik 691381030003 Digi Key 732 6056 ND Pin Signal Remark 1 PWR 5V 28V DC 2 GND 3 SHIELD Chassis GND Desc...

Страница 8: ...iation 6 2 Auto Role Switch DIP2 DIP2 controls a proprietary Auto Role Switch function When turned on the Factory Link SPE M automatically determines the T1 link role master or slave This function is...

Страница 9: ...it provides direct access to the register sets of the integrated PHYs It provides the following functions Controller 100BASE T1 connection 100BASE TX connection Media Converter Selection Firmware Info...

Страница 10: ...cs Using the T1 PHY Cable Diagnostics cable faults and their distance from the device can be detected During the measurement the link is broken The distance measurement has a tolerance of 1 5m Cable D...

Страница 11: ...been read entering the address data in the Device and Register fields Entering a value in this field will result in a write operation to the respective register Written values are read back and displa...

Страница 12: ...RoHS Restriction of the use of certain hazardous substances dt Restriction of use certain dangerous substances 8 3 CE Marking The i novative Factory Link SPE M has the CE mark This device complies wi...

Отзывы: