page 21
In the section „
Life Cycle Settings
“ you can find further Life Cycle specific settings. The Life Cycle
mode (4) of the OABR Multi-Media-Switch is set with the DIP switch 4. In the „
Always On
“ positi-
on, the switch does not participate in the life cycle process. If „Customized“ is selected, the device
behaves according to the specified Life Cycle parameters.
For the life cycle, the following must be set accordingly.:
• Life Cycle Trigger Mode (5): Specifies the operating mode. Here can be swiched
between „
CAN only
“, „
ETH_ON only
“ and „
ETH_ON & CAN
“.
• Time to sleep (6): Specifies the time in milliseconds where the device goes to sleep
mode.
In section „
ETH_ON Settings
“, the settings for the bi-directional wake-up line (ETH_ON) can be
configured. The ETH_ON wake-up line is in idle state at low level. If the mode „
ETH_ON only
“ or
„
ETH_ON & CAN
“ is selected, the OABR Multi-Media-Switch responds to a high level of the
ETH_ON. The pulse width stimulus threshold can be set under Pulse Threshold (7) in the millise-
cond range.
The OABR Multi-Media-Switch is also able to actively send a trigger pulse on the ETH_ON line.
The pulse width (8) can also be specified in the millisecond range. By means of the „
Send
“ button
(9) the pulse is generated.
In the section „
CAN Settings
“ mask- and filter settings for the CAN Life Cycle Management can be
specified. In this case, any message can be received (10), which also wakes up the OABR Multi-
Media-Switch. Alternatively you can set Filter criteria (11), whereby the switch is then awakened
by one or more specific CAN messages with a special identifier. Here, two filter parameters and
one mask parameter (12) can be set. The mask parameter specifies the relevant bits of the identi-
fier, which can also be used to set identifier groups.