manualshive.com logo in svg
background image

EMS i-MO 200-S Series Hardware Installation Guide

 

Version 

2.0

 

 

 

ELECTRONIC MEDIA SERVICES LIMITED

   

PASSFIELD BUSINESS CENTRE, LYNCHBOROUGH ROAD, LIPHOOK, HAMPSHIRE, GU30 7SB, UK

 

Tel:

 01428 751655 | 

Fax:

 01428 751654 | 

E-mail:

 [email protected]

 

Page 

6

 of 

20

 

 

Do not place containers of liquids on the device or allow the device to come in contact with liquids. 

Do not place near or on a source of heat. 

Product Disposal Warning 

Disposal of this product must be handled according to all national laws and regulations. 

See  

Appendix C

 for details. 

General Electrical Safety Warnings for EMS Hardware Equipment 

Radio Frequency Interference 

You can reduce or eliminate the emission of radio frequency interference (RFI) from your site wiring by using 
twisted-pair network cabling with a good distribution of grounding conductors. If you must exceed the 
recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data 
signal when applicable. 

Electromagnetic Compatibility 

If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or 
radio transmitters, you might want to seek expert advice. Strong sources of electromagnetic interference 
(EMI) can destroy the signal drivers and receivers in the router and conduct power surges over the lines into 
the equipment, resulting in an electrical hazard. It is particularly important to provide a properly grounded 
and shielded environment and to use electrical surge-suppression devices. 

AC Power Electrical Safety Guidelines 

The i-MO 200-S Series appliance requires an AC supply of 100-240Volts, 50/60Hz and can draw a current of 
up to 2 Amps. 

i-MO routers are shipped with a three-wire electrical cord with a grounding-type plug that fits only a 
grounding-type power outlet. Do not circumvent this safety feature. Equipment grounding should comply with 
local and national electrical codes. The power cord serves as the main disconnecting device. The socket 
outlet must be near the router and be easily accessible. 

 

 

 

Содержание 200-S Series

Страница 1: ...Hardware Installation Guide i MO 200 S Series Bonding Router Hardware Installation Guide for the i MO 200 S Series Appliance...

Страница 2: ...onal 7 2 How to install Modems optional if not already fitted 7 3 How to install SIM cards optional if not already fitted 9 4 How to close the appliance optional 10 5 How to attach the WiFi antenna 10...

Страница 3: ...S CENTRE LYNCHBOROUGH ROAD LIPHOOK HAMPSHIRE GU30 7SB UK Tel 01428 751655 Fax 01428 751654 E mail imo ems uk com Page 3 of 20 Reduction of Hazardous Substances 18 Appendix D Warranty Information 19 EM...

Страница 4: ...VICES LIMITED PASSFIELD BUSINESS CENTRE LYNCHBOROUGH ROAD LIPHOOK HAMPSHIRE GU30 7SB UK Tel 01428 751655 Fax 01428 751654 E mail imo ems uk com Page 4 of 20 I MO Appliance Identification Guide The fol...

Страница 5: ...hassis covers or sheet metal parts unless instructions are provided in this documentation Such an action could cause severe electrical shock Do not push or force any objects through any opening in the...

Страница 6: ...onductor for each data signal when applicable Electromagnetic Compatibility If your site is susceptible to problems with electromagnetic compatibility EMC particularly from lightning or radio transmit...

Страница 7: ...appliance is switched off and the power cable is removed Gently remove all aerials if connected Step 2 Place the unit on a clean soft surface that will not scratch the case Gently undo the 4 screws a...

Страница 8: ...28 751654 E mail imo ems uk com Page 8 of 20 Step 2 The first modem must be placed in the Modem A position as shown in image 1 above Insert the modem as shown image 4 above then push down into place a...

Страница 9: ...this position Gently undo the black tape covering the connector Step 6 Connect the end of Modem Aerial connector B to Modem B The cable ends click onto the small fittings on the modems which are label...

Страница 10: ...it is fully inserted as shown in image 6 above Gently by hand insert the back panel screws in the holes and hand tighten The case is made from aluminium so it is fragile Once the screws have been tigh...

Страница 11: ...network and ADSL cables optional The i MO appliance provides two Ethernet ports at the rear Each of these can be individually configured as WAN or LAN ports Network cables not provided can be connect...

Страница 12: ...Fax 01428 751654 E mail imo ems uk com Page 12 of 20 9 How to switch the power on The power for the unit is switched on when the mains power is connected and switched on there is no separate power swi...

Страница 13: ...imo ems uk com Page 13 of 20 10 Status display The LED display shows the status of up to two mobile connections plus the overall status of the link Link Status This shows the overall status of the lin...

Страница 14: ...netic Fields 3kHz to 300 GHz National Council on Radiation Protection and Measurements NCRP Report 86 1986 Biological Effects and Exposure Criteria for Radio Frequency Electromagnetic Fields Internati...

Страница 15: ...ization International Commission on Non ionizing Radiation Protection ICNIRP and include safety margins designed to assure the protection of all persons regardless of age and health The guidelines use...

Страница 16: ...TS 2 1 GHz 1900 2170 GHz Gain 5 dBi Polarization vertical Rod Length 290mm Power maximum 20 W Cable length 2500 mm Cable type RG 174 Connector SMA male VSWR 1 5 Technical Data GSM UMTS Specifications...

Страница 17: ...to create an omni directional broadcast pattern To achieve this pattern the antenna should be mounted clear of any obstructions to the sides of the radiating element If the mounting location is on th...

Страница 18: ...his device is subject to the Waste from Electrical and Electronic Equipment WEEE directive of the European Union The reason for separating WEEE and batteries from other waste is to minimize the potent...

Страница 19: ...for paying all parts labour and shipping charges The warranty described above shall apply to all repaired or replaced Product for a period of 90 days from the date of return to you or the balance of t...

Страница 20: ...ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR THEY ARE FORESEEABLE OR FOR CLAIMS BY ANY THIRD PARTY MAXIMUM AGGREGATE LIABILITY OF THE AFOREMENTIONED PERSONS SHALL NOT EXCEED THE AMOUNT PAID BY YOU FO...

Отзывы: