Step 3

Reattach and secure cover with set screw.

WALL SENSOR INSTALLATION - INSTALLATION 

WITHOUT ELECTRICAL BOX

Step 1

Drill 1-1/2” hole through wall. The location will vary based on the 

existing flush valve installation. Typically installed 21” about the 

fixture on the centerline.

Step 2

Drill openings for wall anchors using 3/16” drill. See dimensional 

drawing. Insert wall anchors.

3

16 "

5

3

16 "

5

1 12 "

38

 1 58 "

41

 

 1 58 "

41

 

 3 14 "

83

 

COMMERCIAL CUTSHEET

TO CHANGE

ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-CUTSHEET-TEMPLATE.sldstd

SET NORMAL LINE THICKNESS TO .004

SET THIN LINE THICKNESS TO .002

ADJUST SHEET SCALE TO FILL PAGE

SET FRACTIONAL DISPLAY TO VERTICAL

SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING

TEXT SHOULD BE ALL CAPS

DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)

TEMPLATE INFORMATION

PAGE SIZE 3"x3"

CENTURY GOTHIC SIZE 8 FONT

ONE-TIME SYSTEM SETTING CHANGE

DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK

SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK

SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY

SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600

PARAMETERS TO MEET

INDICATE A CENTERLINE OF FIXTURE

INDICATE A CENTERLINE OF SUPPLY FOR CONCEALED SYSTEMS

INDICATE A CENTERLINE OF WALL SENSOR WHEN APPLICABLE

Step 3

Loosen set screw on face plate. Remove cover by pulling out, 

then up.

Содержание COBALT Pro 101674

Страница 1: ...mercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years...

Страница 2: ...box 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE A...

Страница 3: ...ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square profile O ring into groove on bottom of flush valve cap assembly Place flush...

Страница 4: ...ttach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Step 1 Drill 1 1 2 hole through wall The location will vary based on the existing flush valve install...

Страница 5: ...e through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw INTERFACE MODULE INSTALLATION Step 1 Open interface module Mount to flat...

Страница 6: ...sh valve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the...

Страница 7: ...ion button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and release pro...

Страница 8: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...

Отзывы: