Page 19
7.5.5.
Fill the exciter with exciter oil.
DO NOT overfill – overfilling can result in excessive temperatures in the exciter.
7.5.6.
Apply pipe sealant to pipe plug and reinstall into top of exciter housing.
7.5.7.
Reinstall deck, V-belt(s) and belt guard.
HYCP5030
HYCP6570
HYCP9070
Exciter oil – ml
60
80
100
Exciter oil - type
Automatic Transmission Fluid Dextron III, Mercon, EXXON
(ESSO) NUTO H-32 or its equivalent
7.6.
Engine maintenance.
7.6.1.
Refer to the Engine Manual included in your plate compactor for the
information on engine maintenance. Your engine manual provides detailed
information for performing the tasks.
11.
TROUBLESHOOTING
PROBLEM
CAUSE
REMEDY
Engine fails to start
1 - Spark plug wire disconnected 1 - Attach spark plug wire
securely to spark plug
2 - Out of fuel or stale fuel.
2 - Fill with clean, fresh gasoline
3 - Throttle control lever not in
correct starting position
3 - Move throttle control lever
to start position