background image

 

 

 

 

 

9.

 

DISPOSAL & RECYLING.

 

 

9.1

 

Do not dispose of electric equipment together with household waste material! In observance 

of European Directive 2012/19/EC on waste electrical and electronic equipment and its 
implementation in accordance with national law, electric equipment that have reached the end of 
their life must be collected separately and returned to an environmentally compatible recycling 
facility. If electrical appliances are disposed of in landfills or dumps hazardous substances can leak 
into the groundwater and get into the food chain, damaging your health and well-being. 
19.2  For further information on the disposal of this product, please contact your dealer or your 
nearest domestic waste collection service. 

 

9.3

 

Reduce – Reuse - Recycle unwanted materials instead of disposing of them as 

waste. All tools, accessories and packaging should be sorted, taken to a recycling 
centre and disposed of in a manner which is compatible with the environment. 

 

9.4

 

When the product is no longer required, it must be disposed of in a manner 

which is compatible with the environment. 

 

10.

 

TROUBLESHOOTING.

 

 

Problems

 

Reasons

 

Solutions

 

Compressor does not run.

 

1.

 

Voltage cuts off. 

 

2.

 

The main voltage is too low. 

 
 

3.

 

External temperature is too low. 

4.

 

Motor overheats.

 

1.

 

Check cable, plug, fuse and 

outlet. 
2.

 

Avoid the long extension 

cords. Use the cable with the 
sufficient wire cross section. 
3.

 

Not operate below 5 

℃ 

4.

 

Cooling down the motor 

may eliminate the failure.

 

Compressor runs but has 
no pressure.

 

1.

 

The valve (18) leaks 

2.

 

The seal is broken. 

 

3.

 

The condensation drain plug 

(4) has become loose.

 

1.

 

Replace check valve. 

2.

 

Get broken seal 

replaced by a specialist. 
3.

 

Tighten the screw by hands. 

Check the seals on the screw 
and replace it if necessary.

 

Compressor is running, 
pressure is displayed on 
the gauge, but tools do 
not run.

 

1.

 

Hose connections leak. 

 

 

2.

 

Quick release coupling leak. 

 
 

3.

 

The pressure is set too low

 

1.

 

Check the compressed air 

hose and tool, replace them if 
necessary. 
2.

 

Check the quick release 

connections 
and replace them if necessary. 
3.

 

Increase the pressure 

regulator adjustment knob. 
Check for hose leak between 
regulator and tool.

 

Page 14

Rev 2

Содержание HY2524

Страница 1: ......

Страница 2: ...7 4 INSTALLATION INSTRUCTIONS 7 5 ADDITIONAL SAFETY 7 9 6 INSTALLATION COMISSIONING 10 11 7 TECHNICAL DATA 12 8 CLEANING MAINTENANCE 12 13 9 DISPOSAL RECYCLING 14 10 TROUBLESHOOTING 14 11 GENPOWER CON...

Страница 3: ...perty 1 2 Some or all of the following PPE Warning Signs and symbols may appear throughout this manual and you must adhere to their warning s Failure to do so may result in personal injury Personal Pr...

Страница 4: ...cables plugs and connections for the following 1 3 3 1 Are intact and have no signs of damage to include but not limited to bare wires chaffing cuts and loose wiring If there are any signs of damage...

Страница 5: ...Picture 3 1 Inlet air filter 2 Compressor 3 Oil level indicator 4 Air tank 5 Foot 6 Handle 7 ON OFF switch 8 Pressure gauge 9 Pressure relief valve 10 Quick relase outlet 11 Pressure regulator 12 Tan...

Страница 6: ...2 PARTS Continued Accessory kit a Wheels x 2 b Wheel bolts x 2 c Oil filler cap x 1 d Rubber foot x 1 e Nut Bolt for foot x 1 f Air filter x 1 Page 6 Rev 2...

Страница 7: ...r where it will not get wet i e outside in the rain 5 1 3 2 Do not use the compressor in the damp or wet conditions 5 1 3 3 Provide and use adequate lighting 5 1 3 4 Always use the compressor far away...

Страница 8: ...re in good order and function correctly 5 1 14 2 Check that all the functional parts are fine make sure no part is damaged 5 1 14 3 All parts must be installed correctly and the device must be checked...

Страница 9: ...smoke in the working area and whilst using the compressor 5 3 5 DO NOT allow any sources of ignition such as matches lighters naked flames and any other sources of ignition such as sparks from grindi...

Страница 10: ...n pass bolt through wheel frame g next put washers d and e over bolt finally secure the bolt using nut f DO NOT overtighten the bolt the wheel must be left free to spin on the bolt axle 6 1 3 Using pa...

Страница 11: ...extension cables etc are sufficient to supply the compressor without voltage drop which can prevent the motor from starting 6 4 3 We do not guarantee the performance and motor running at temperatures...

Страница 12: ...580 Net Weight kg 28 Tank material Rolled steel 8 CLEANING MAINTENANCE Before any cleaning or maintenance work the compressor should be disconnected from the mains supply To prevent the risk of burnin...

Страница 13: ...oil 9 5 4 Unscrew the oil drain bolt on the compressor pump so that the oil runs out 9 5 5 If the oil does not completely run out we recommend the compressor is leant over in the direction of the drai...

Страница 14: ...e product is no longer required it must be disposed of in a manner which is compatible with the environment 10 TROUBLESHOOTING Problems Reasons Solutions Compressor does not run 1 Voltage cuts off 2 T...

Страница 15: ...chinical service genpower co uk 11 4 4 Web site www hyundaipowerequipment co uk 12 DECLARATIONS of CONFORMITY 12 1 Genpower Ltd confirms that this Hyundai product conform to the following CE directive...

Страница 16: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 info hyundaipowerequipment co uk...

Отзывы: