6.2
Installation (replacing) of the air filter.
6.2.1
.1 Remove the shipping plug (Picture 4) with a screwdriver or a similar tool. Unscrew
the air filter (1) with the wing nut (a) attached to the machine (Picture 5).
6.3
Filling with oil.
6.3.1
Use a screwdriver to remove the oil filler cap (Picture 6 (a)) and fill with oil into
machine as shown (b) in the oil filler (Picture 7).
6.4
Electrical connections..
6.4.1
The compressor is supplied with a power lead to three pin earthed plug. This can be
connected to any power socket 230V ~ 50Hz, which is protected by a 16A electrical supply.
6.4.2
Before running the machine for the first time, please make sure that long supply cable,
extension cables, etc, are sufficient to supply the compressor without voltage drop which can
prevent the motor from starting.
6.4.3
We do not guarantee the performance and motor running at temperatures be low
temperature of 5
℃
.
6.5
Turning the compressor ON/OFF.
6.5.1
By pulling the red button (page 5 item 7) the compressor will be turned
ON.
6.5.2
To switch it OFF , push the red button (page 5 item 7).
6.6
Quick release coupling.
6.6.1
Connecting - Pull the hose connection sleeve back then push the air hose coupling into
the quick release coupling sleeve. Once the sleeve is released it will automatically back to lock the
coupler in place.
6.6.2
Dis-connecting - Pull the hose connection sleeve back then pull the air hose coupling
from the quick release coupling sleeve. Once the sleeve is released it will automatically return to its
normal position.
Page 11
Rev 2