15
1. Ensure the Spray Tip (5) is rotated forward to the spray position with the arrow on the tip facing
forward (Fig.7a).
2. Perform “Pressure Relief Procedure”.
3. Turn ON the machine by pressing 1” on the On/Off Switch (13) (Fig.7b).
4. Unlock the Spray Gun Trigger (3) (Fig.7c).
5. Set the Prime/Spray Switch (11) to “SPRAY” position (Fig.7d).
6. Stand about 30cm away from area to be sprayed and maintain this distance (Fig.7e). Pull the
spray gun Trigger (3) to start spraying.
NOTE: The motor will cycle ON and OFF while spraying to regulate pressure. This is normal.
IMPORTANT!
When finished spraying, perform Pressure Relief Procedure.
IMPORTANT!
If you have not finished painting with your airless sprayer and want to take a
short break (30-60 minutes), do not leave paint sitting inside the pump. Follow the cleaning
instructions to prevent paint from drying inside the pump and hose.
Once you’re ready to begin work again, simply follow the Spraying Procedures. Once properly
primed again, aim the spray gun into a waste bucket and allow 30 seconds for any leftover cleaning
solution to be flushed out of the system. Then resume painting as normal.
IMPORTANT! Mineral Turpentine SHOULD NOT be mixed with water at any stage during the
cleaning process.