6-62
Hydraulic pump performance cycle time.
10. CYCLE TIME TEST
SPECIFICATION
Oil temperature
45
±
5˚C (113
±
9˚F)
Engine speed
High idle
·
Function
Operating conditions
Maximum cycle time (seconds)
HL955 / XTD
HL955TM
Boom raise
Bucket flat on ground to full height
5.8
5.8
Boom lower (float)
Full height to ground level
3.9
3.9
Bucket dump
Boom at full height
1.2
2.0
Bucket rollback
Boom at full height
1.6
2.2
Steering (No. of turns)
Frame stop to stop
3.5 turns
Function
Operating conditions
Maximum cycle time (seconds)
Boom raise
Bucket flat on ground to full height
while holding steering over relief
10
Содержание HL955