background image

                GR8 DIAGNOSTIC TESTER/CHARGER TOOL AND BATTERY WARRANTY POLICY

 

 

TSB #: 18-EE-003 

Page 7 of 10 

 

SUBJECT: 

5. 

Connect only the Charger unit’s large clamp set to the vehicle’s battery making sure that the 
black clamp is connected to the battery negative “-“ terminal and the red clamp is connected 
to the battery positive  

“+” terminal. GR8 display will warn if you have connected it 

backwards. 

6. 

Perform the following instructions showing the GR8 screens (as shown from left to right of 
each row) that will occur when a “Good Battery” result is reached after charging: 

 

 

Press YES to start charging 

 

Connect large clamps 

 

Diagnostic charge is in progress 

 

Charge status being displayed 

 

Good Battery condition reached 

 

Full Charge Complete 

 

 
If the Diagnostic Charge results in “Good Battery”, attach both Battery Test 
printout 

of the “Charge & Retest” result and the Diagnostic Charge “Good 

Battery” result per example of “Printout #B” on page 9. 
 

 NOTICE

 

Содержание GR8

Страница 1: ...if it has not been in a discharged state for an extended period of time Hyundai Factory Installed and Replacement Battery Information can be found at Hyundai Flash Drive P N Reference Materials GR8 Battery Test clamps or Charger clamps must be connected directly onto the battery posts Do not connect to the jumper terminals in the engine compartment The correct battery type selection either Flooded...

Страница 2: ...e initial diagnostic charge test finds that the charge will not revive the battery it will usually indicate Replace Battery within 20 minutes on average 3 Should the battery pass the Diagnostic Charge test it will continue charging until the battery reaches a full charge condition which can take up to 1 5 hours and indicate Good Battery by automatically printing out a printout when completed succe...

Страница 3: ...pendent of the charger unit after a battery charge is in process The cable from the base may be disconnected and wireless communication exists to the Charger unit The cable should be reconnected when docked on the charger Either the small battery tester clamps or large charger clamps can be connected to a battery at a time NOTICE NEVER connect both sets of small and large clamps to a battery as it...

Страница 4: ...nnected to the battery negative terminal and the red cable s clamp is connected to the battery positive terminal GR8 display will warn if you connected in backwards 3 Follow these screen by screen instructions from left to right for each row This example shows screens that will occur for the battery condition of Charge Retest Select or add yourself as a user Connect small clamps only Select Batter...

Страница 5: ...lect vehicle type Select either FLOODED or AGM type Enter SAE CCA rating of battery Enter RC rating of battery Follow instruction and select NEXT Testing is in progress Enter Repair Order number Test Result Print for the R O Always print out the Battery Test result to attach to the Repair Order NOTICE ...

Страница 6: ...applicable Press YES or select Diagnostic at Main Menu Repair Action Warranty Claim Type Battery Test Result Diag Charge Result None None GOOD BATTERY Charge is not applicable GOOD RECHARGE Dealer optional charge method as per Charge by GR8 or idle engine for 30 minutes None REPLACE BATTERY BAD CELL Charge is not applicable Replace Battery Replace 37110R00 only Add Printout A to R O CHARGE RETEST ...

Страница 7: ...nnected it backwards 6 Perform the following instructions showing the GR8 screens as shown from left to right of each row that will occur when a Good Battery result is reached after charging Press YES to start charging Connect large clamps Diagnostic charge is in progress Charge status being displayed Good Battery condition reached Full Charge Complete If the Diagnostic Charge results in Good Batt...

Страница 8: ...ostic Charge attempt Charge Status Screen Enter R O number Charge NG Replace Battery If the Diagnostic Charge resulted in Replace Battery claim the Op Code 37110A00 for the battery charge attempt and Op Code 37110R00 for Replace Battery The Battery Test printout for Charge Retest result and the Diagnostic Charge result must be attached as per example Printout C of the page 9 NOTICE ...

Страница 9: ...LACE 37110R00 only CHARGE 37110A00 only CHARGE 37110A00 REPLACE 37110R00 BATTERY TEST REPLACE BATTERY 1 BATTERY TEST CHARGE RETEST 1 BATTERY TEST CHARGE RETEST 2 DIAGNOSTIC CHARGE GOOD BATTERY 2 DIAGNOSTIC CHARGE REPLACE BATTERY Hh ha h sha H HH ihDIUH Enter this 11 digit warranty code into the claim based on results as indicated Printout s that must be attached to the Repair Order based on the Ba...

Страница 10: ... BATTERY 0 3 M H Battery Test CHARGE RETEST and Diagnostic Charge REPLACE BATTERY Ex Printout C Must be entered in order as below 37110R00 37110A00 REPLACE BATTERY CHARGE BATTERY Per LTS 0 3 M H Initial Step BATTERY TEST Printout Result 2nd Step DIAGNOSTIC CHARGE Printout Result Warranty Code is entered from BATTERY TEST Printout DIAGNOSTIC CHARGE Printout REPLACE BATTERY Not applicable Do not att...

Отзывы: