18
negative). Check the voltage is above 12.3V, if not the battery should be
charged.
2.
Check the voltage, once a month. The voltage of a standard battery is 12.5v-
13.6v.
3.
If the battery voltage is too low, it should be removed and re-charged.
4.
Keep the battery in a cool, dry place. It is important to clean the battery every
three months and re-charge every 6 months.
- The battery electrolyte contains sulphuric acid. Protect your eyes, skin and clothing. In case
of contact, flush thoroughly with water and get immediate medical attention, especially if it
has made contact with your eyes.
- The battery vents can give off hydrogen gas, which can be highly explosive. Do not smoke
or allow flames or sparks near the battery, especially during charging.
8.8 Check the alternator carbon brushes and slip rings
Check the generators carbon brushes and slip rings regularly. Readjust if there is a poor
contact or the brushes are worn.
9. Long-Term Storage
If storing the generator for long periods of time, make the following operations.
1.
Operate the engine for 10 minutes and then stop.
2.
Stop the engine. Drain the engine oil whilst the engine is still warm and refill with
fresh oil.
3.
Remove the screw plug on the cylinder head cover and fill with 2cc of engine oil,
then put the plug back in place.
4.
Turn the engine for 2-3 seconds with the decompression lever set at the non-
compression position and the starting key set at the 'START' position. (Do not start
the engine.)
5.
Wipe off the oil and dirt from the engine and store in a dry place.