13
- Do not loosen or readjust either the engine speed limiting bolt or the fuel injection limiting
bolt as this will cause the performance of the generator to be affected.
5.2 Checks during the running of the generator
1.
Check that there is no abnormal sound or vibration.
2.
Check that the engine is running smoothly without mis-fire.
3.
Check the colour of the exhaust- Is it too black or white?
4.
Check that there are no oil or fuel leaks.
If you notice any of the above, stop the engine and find the fault. Please contact Genpower
for assistance if required.
- If the engine has been running, the muffler will become very hot. Be careful not to touch
the muffler until it has had time to fully cool down.
- Never refuel the fuel tank whilst the engine is still running.
6. LOAD
- Do not start 2 or more appliances simultaneously- start them one by one.
- Do not use floodlights together with other appliances
6.1
230v AC Use
1.
After switching ON the main breaker switch, check the voltmeter reading. The
voltmeter should point to 230v ± 5% (50Hz) for single-phase and 400v ± 5% for three
phase generators, the load can now be applied.
Connect the equipment to the generator in correct order. Connect the loads with the largest
motor first, then the smaller items. If the generator is overloaded the main breaker will trip.
- Reset the breaker trip switch and reduce the electrical load on the circuit. Wait a few
minutes before resuming operation.
6.2 12v DC Use
1.
DC terminals are only for charging 12V batteries.
2.
Set the main AC breaker switch to the 'OFF' position whilst charging.
Содержание DHY6000SE/LR
Страница 1: ......
Страница 2: ...2 Licensed by Hyundai Corporation Korea ...
Страница 20: ...20 11 Wiring Diagram ...
Страница 21: ...21 12 Service Record Sheet Date Hours Maintenance undertaken Name ...
Страница 22: ...22 13 Notes ...
Страница 24: ...Licensed by Hyundai Corporation Korea ...