Hyundai power products HY6500SEi Скачать руководство пользователя страница 5

OIL WARNING SYSTEM 
When the oil level falls below the lower level, the engine stops 
automatically. Unless you refill with oil, the engine will not start again. 
 
ENGINE SWITCH 
The engine switch controls the ignition system. 

    RUN 

Ignition circuit is switched on. The engine can be started. 

    STOP 

Ignition circuit is switched off. The engine will not run. 

    START 

Starting circuit is switched on. The starter motor starts.

   

 
ECONOMY CONTROL SWITCH

 

 

When the economy control switch is turned ON, the economy control 
unit control the engine speed according to the connected load. The 
results are better fuel connection and less noise.

 

 

 
DC CIRCUIT PROTECTOR 
The DC circuit protector turns off automatically when the load exceeds 
the generator rated output.

 

 

CAUTION:   

 

Reduce the load to within specified generator rated output if the DC 
circuit protector turn off.

 

 

 

OUTPUT RESET

 

 

Push reset button for continuous 2 seconds, the generator will recover 
the AC output when the generator stop AC output under overload 
protect.

 

 

NOTE:   
Please reduce the load of generator to ensure that the total load is within 
the rated power. 
 

 

 

 

 

STOP

RUN

START

ENGINE

SWITCH

ON

OFF

ECON. SW

 

RESET

 

Содержание HY6500SEi

Страница 1: ...INVERTER GENERATOR User s Manual Licensed by Hyundai Corporation Korea HY6500SEi EN ...

Страница 2: ... the instructions carefully In doing so you will ensure the safety of yourself and that of others around you andyoucanlookforwardtoyourpurchasegivingyoulongandsatisfactoryservice CONTENTS SAFETYINFORMATION 2 CONTROLFUNCTION 3 PRE OPERATIONCHECK 6 OPERATION 7 PERIODICMAINTENANCE 12 TROUBLESHOOTING 15 STORAGE 16 SPECIFICATION 17 WIRINGDIAGRAM 18 1 ...

Страница 3: ...andchangeyourclothes When operating or transporting the machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fueltank ENGINEANDMUFFLERMAYBEHOT Placethemachineinaplacewherepedestriansorchildrenarenotlikelytotouchthemachine Avoidplacinganyflammablematerialsneartheexhaustoutletduringoperation Keepthemachineatleast1m 3ft frombuildingsorotherequipment ortheenginemayoverhe...

Страница 4: ...llevelgauge 7 Muffler 8 Battery 9 Airfilter 10 Brakelever 11 Wheel 12 Oilfillercap 13 Oildrainplug 14 Chokerod 15 Fuelcock 16 Engineswitch 17 Datadisplayinstrument 18 ACprotector16A 19 Ground earth terminal 20 ATSreceptacle 21 ACreceptacle 22 USBOutput 23 DC12Vreceptacle 24 DCprotector 25 Outputreset 26 Economycontrolswitch 27 Remotecontrol 2 3 4 6 5 7 13 12 11 10 8 1 9 16 15 26 25 24 21 23 22 17 ...

Страница 5: ...ON the economy control unit control the engine speed according to the connected load The resultsarebetterfuelconnectionandlessnoise DCCIRCUITPROTECTOR The DC circuit protector turns off automatically when the load exceeds thegeneratorratedoutput CAUTION ReducetheloadtowithinspecifiedgeneratorratedoutputiftheDC circuitprotectorturnoff OUTPUT RESET Push reset button for continuous 2 seconds the gene...

Страница 6: ...lfromthetanktothecarburetor DATADISPLAYINSTRUMENT Normal ShortCircuit OverCurrent Maintenance HighVoltofACoutputwithE1ACindicated HighVoltDCmotherlinewithE1DCindicated LowVoltofACoutputwithE1ACindicated LowVoltofDCmotherlinewithE2DCindicated MCUHighTemperaturewithE3indicated IGBTHighTemperaturewithE4indicated LowOilwithyellowlighton FAULT DefectsorOverloadswithredlighton OUTPUT NormalRunningwithgr...

Страница 7: ... not to admit dust dirt water or other foreign objects into fuel Do notfill abovethe topofthefuel filter or it may overflow when the fuelheatsuplaterandexpands Wipeoffspiltfuelthoroughlybeforestartingengine Keepopenflamesaway CHECKENGINEOIL Make sure the engine oil is at the upper level of the oil filler hole Add oil asnecessary Removeoilfillercapandchecktheengineoillevel If oil level is below the...

Страница 8: ...llthecoverandtightenthescrew NOTE Recommendedbattery 12V18AH OPERATION NOTE Thegeneratorhas beenshipped withoutengineoil Fill withoil orit willnotstart Donottiltthegeneratorwhenaddingengineoil Thiscouldresultin overfillinganddamagetotheengine STARTINGTHEENGINE NOTE Beforestartingtheengine donotconnecttheelectricapparatus A Electricstart 1 TurnthefuelcocklevertotheONposition 2 PulloutchokerodtotheC...

Страница 9: ...itchtotheRUNposition Connect the communication wire between the generator and ATS unit ConnectATSMAINSPOWERtotheelectricsupplygrid ConnectATSGENERATORPOWERtothegeneratorACoutput ConnecthomeappliancestoATSOUTPUT SwitchATSatthepositionofAUTO whentheelectricsupply stops the generator would automatically started to power the home appliances when the electric supply goes normal the generator would stop...

Страница 10: ...einverterunitoverheats ortheACoutput voltagerises Theelectronic breakerwillthenactivate stoppingpowerto the generation in order to protect the generator and any connected electric devices The overload indicator light red will turn on then the generatorwillstopoutput Ifsopleasefollowthefollowingsteps a Turnoffanyconnectedelectricdevices b Reduce the total wattage of connected electric devices withi...

Страница 11: ...e fully charged battery shall be within 1 26 to1 28 Itisrecommendedtoconfirmeveryanhour b Connect between the DC output socket and the battery terminals using the charging leads The leads shall be connected making sureofthe and polarity c The DC circuit protector is to be set to ON after confirming the connection iftheprotectorisinOFFposition CAUTION Besurethe economy controlswitchisturnedoffwhile...

Страница 12: ...GINE 1 Turn off the power switch of the electric apparatus or disconnect any electricdevices 2 TurntheengineswitchtoSTOPposition Clickremoteswitchtothe position 3 TurnthefuelcocklevertoOFF STOP ENGINE SWITCH OFF 11 ...

Страница 13: ...ance Check and adjust when engine iscold FuelLine Check fuel hose for crack or damage Replaceifnecessary Exhaust System Check for leakage Retighten or replacegasketifnecessary Checkmufflerscreen Clean replaceifnecessary Carburetor Checkchokeoperation Cooling system Checkfandamage Starting system Checkrecoilstarteroperation Idlespeed Checkandadjustengineidlespeed Fittings Fasteners Check all fittin...

Страница 14: ...endedengineoil seepage17 APIService SJ CAUTION Besurenoforeignmaterialentersthecrankcase Donottiltthegeneratorwhenaddingengineoil Thiscouldresultin overfillinganddamagetotheengine Cleantheoilfiltereveryother100hr AIRFILTER Maintaining an air cleaner in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engin...

Страница 15: ...ltankcapandfilter 2 Cleanthefilterwithsolvent Ifdamaged replace 3 Wipethefilterandinsertit WARNING Besurethetankcapistightenedsecurely MUFFLERSCREEN WARNING The engine and muffler will be very hot after the engine has been run Avoid touching the engine and muffler while they are still hot with anypartofyourbodyorclothingduringinspectionorrepair 1 Removethecover 2 Removethemufflerscreen Standardele...

Страница 16: ...pplyfuel Fuelintank FueltankcapairventknobtoON fuelcockknobtoON Cloggedfuelline Cleanfuelline Cloggedcarburetor Cleancarburetor 2 Engineoilsystem Insufficient Oillevelislow Addengineoil 3 Electricalsystems Poorspark Sparkplugdirtywithcarbonorwet Removecarbonorwipesparkplugdry Faultyignitionsystem Consultdealer 4 Compressioninsufficient Wornoutpistonandcylinder Consultdealer Generatorwon tproducepo...

Страница 17: ...NE 1 Remove the spark plug pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole andreinstallthesparkplug 2 Usetherecoilstartertoturntheengineoverseveraltimes withignitionoff 3 Pulltherecoilstarteruntilyoufeelcompression 4 Stoppulling 5 Cleanexteriorofthegeneratorandapplyarustinhibitor 6 Storethegeneratorinadry well ventilatedplace withthecoverplaceoverit 7 Thegener...

Страница 18: ...m 88 64 Displacement 389cc Max Output 7 5kW 3600rpm Fuel RegularAutomobileGasoline FueltankCapacity 18 5liters RatedContinuousOperation 4h30min 100 Load Lubricatingoil SAE10W30 LubricatingoilCapacity 1 1liter StartingSystem ElectricStarter Remotestarter ATS Ignitionsystem C D I SparkPlug Type F6RTC DIMENSION Netdimension L W H 750 537 630 Overalldimension L W H 825 615 700 NetWeight 89kg DryWeight...

Страница 19: ... MAGNET ELECTRIC LOCK GROUND TERMINAL BL Bu BL W W G IGNITION CONTROLLER ECON SWITCH STEPPER MOTOR ASSY GRAY BLACK WHITE PI Gr PINK BL W ORANGE YELLOW O Y BL Bu BLACK BLUE BROWN RED Br R W WHITE G GREEN P PURPLE W BL P W IGNITION COIL BL O R Y G R BL P W Gr R BL Bu BL FUSE 5A O Y W R BL O R Y W BL Bu R W REMOTE ATS UNIT RECTIFIER DC 12V OUTPUT Bu Bu Bu Bu Bu BL FUSE 15A R DC PROTECTOR 6A YELLOW GR...

Страница 20: ...Licensed by Hyundai Corporation Korea Imported by GRV POWER PRODUCTS S L Av Àlguema 8A 17771 Santa Llogaia d Àlguema Girona T 34 972 673 836 www grvpower com ...