Hytronik HCD038 Скачать руководство пользователя страница 6

Hytronik   Microwave motion sensor   

134

zero-cross point

Alternating current

Zero-cross Relay Operation (HC038V)

Designed in the software, sensor switches on/off the 
load right at the zero-cross point, to ensure that the 
in-rush current is minimised, enabling the maximum 
lifetime of the relay.

7

Wiring Diagram

DALI Driver

DALI Driver

DALI
DALI
L

N

DALI
DALI
L

N

HCD038

DALI
DALI
Push

N

L

L

N

SAM8/SAM11

www.hytronik.com

Содержание HCD038

Страница 1: ...0 O 150 O 0 2mW 5 8GHz 75MHz High Frequency microwave Sensor principle Operation frequency Transmission power Detection range Detection angle 868MHz FSK mode default RF frequency 30m indoor 50m outdoo...

Страница 2: ...ected by the RF sensor antenna SAM8 will operate all other units programmed on the same group via RF transmission The transmission can reach 30 meters indoor and 50 meters in open areas A daylight sen...

Страница 3: ...t off and 2 periods of selectable waiting time motion hold time and stand by period Selectable daylight threshold and freedom of detection area With sufficient natural light the light does not switch...

Страница 4: ...ns in dimming level at night 3 21 40 The light automatically turns on at 10 when natural light is insufficient no motion 5 17 40 2 21 10 Settings on this demonstration Hold time 10min Daylight thresho...

Страница 5: ...e Absence Detection 6 It is easy to forget to switch off the light in office corridor even at home And in many other cases people do not want to have a sensor to switch on the light automatically for...

Страница 6: ...V Designed in the software sensor switches on off the load right at the zero cross point to ensure that the in rush current is minimised enabling the maximum lifetime of the relay 7 Wiring Diagram DAL...

Страница 7: ...100 100 100 SAM8 SAM11 HC034RF slave 4 The person walks to the 3rd floor the 3rd SAM8 switches the light on 100 All slaves on the 3rd floor turn the light on and the SAM8 on the 4th floor switches on...

Страница 8: ...nd Twilight functions are disabled Power output Press the buttons to adjust the light brightness during hold time Brightness Detection range valid for master only Scene program 1 key commissioning 1 P...

Страница 9: ...ing level at 10 20 30 50 HF PIR HF PIR HF PIR are disabled For RF grouping via remote control please refer to steps below Short press Learn Erase button on RC to activate pairing mode and the receiver...

Отзывы: