Configuration Guide
Feature Configuration
49
4.2.6.3
Man Down
Man down alarm is triggered when the radio has been tilted or static for certain time during work.
The alarm is triggered as following:
Step 1
When the tilt (the angle is bigger than the
Trig Tilt Gradient
) or static time equals the difference value
between
Trig Entry Delay Time
and
Pre-Alert Time
, the radio gives alert tone to remind the user of
the alarm.
Step 2
When the
Pre-alert Time
is out, the radio raises the alarm.
To stop the alarm, the user needs to put the radio right or move the radio longer than the
Trig
Exit
Delay Time
.
Path: Common -> PMR ->
Man Down