1.
Intrinsically Safe Radio Information
Caution
¾
Observe the following safety instructions when using the product, so as to ensure safe and
reliable operations. Failure to observe the instructions may result in danger or violation of
applicable regulations.
¾
To avoid possible interference with blasting operations, always turn off the product when you are
near electrical blasting caps, in a blasting area, or in areas posted "Turn off two-way radios". Obey
all signs and instructions.
1.1
Product Marking
The intrinsically safety information of the product is as follows:
Certificate Number
Marking
IECEx FMG 13.0010X
E
x ia IIC T3 Ga
Ex ia I T3 Ma
Ex ia IIIC T160°C Da
FM13ATEX0023X
II 1 G Ex ia IIC T3 –20°C
≤
Ta
≤
+55°C
I M1 Ex ia I –20°C
≤
Ta
≤
+50°C, IP5X
II 1 G Ex ia IIC T3 –20°C
≤
Ta
≤
+50°C, IP5X
II 1 D Ex ia IIIC T160°C –20°C
≤
Ta
≤
+50°C, IP5X
FM16US0013X
Class I Division 1, Groups A,B,C,D T3B
–20°C
≤
Ta
≤
+55
°C
Class I,II,III, Division 1, Groups A,B,C,D,E,F,G T3C
–20°C
≤
Ta
≤
+50
°C,
IP5X
Class I, Zone 0, AEx ia IIC T3B
–20°C
≤
Ta
≤
+55
°C
Class I, Zone 0
, AEx ia IIC T3C –20°C
≤
Ta
≤
+50°C, IP5X
Zone 20, AEx ia IIIC T160°C –20°C
≤
Ta
≤
+50°C, IP5X
FM16CA0013X
Class I Division 1, Groups A,B,C,D T3B –20°C
≤
Ta
≤
+55°C
Class I,II,III Division 1, Groups A,B,C,D,E,F,G T3C –20°C
≤
Ta
≤
+50°C,
IP5X
Zone 0, Ex ia IIC T3B Ga –20°C
≤
Ta
≤
+55°C
Class I, Zone 0, Ex ia IIC T3C Ga –20°C
≤
Ta
≤
+50°C, IP5X