background image

 

 

4.3 

Attaching the Belt Clip 

Step 1 

Remove the screws.   

Step 2 

Align the screw holes on the belt clip with those on the radio’s back, and then tighten the 

screws.  

               

 

4.4 

Attaching the Accessories 

Step 1 

Open the accessory connector cover as shown below.   

 

Step 2 

Align the accessory (such as an audio accessory, or a programming cable) plug with the 

accessory connector.   

Caution: 

 

Do not scrape the silicone rubber surrounding the accessory connector screw hole, in order 

to ensure the waterproof performance of the radio.   

                 

                 

 

Step 3 

Tighten the screw on the plug.   

Содержание PD71XIS

Страница 1: ...r detailed features and operations please refer to the Feature Description and Operation Manual along with the product To avoid body injury or property loss caused by misoperation please read the Safe...

Страница 2: ...ipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Icon Conventions z Indicates functions that are available on digital channe...

Страница 3: ...re compliance with the occupational controlled environment exposure limits always adhere to the following procedures Guidelines Do not remove the RF Exposure Label from the device User awareness instr...

Страница 4: ...mites DAS et ou aux limites d intensit de champ RF les utilisateurs peuvent sur l exposition aux radiofr quences et la conformit and compliance d acqu rir les informations correspondantes EU Regulator...

Страница 5: ...follows Certificate Number Marking IECEx FMG 13 0010X Ex ia IIC T3 Ga Ex ia I T3 Ma Ex ia IIIC T160 C Da FM13ATEX0023X II 1 G Ex ia IIC T3 20 C Ta 55 C I M1 Ex ia I 20 C Ta 50 C IP5X II 1 G Ex ia IIC...

Страница 6: ...t the maximum surface temperature during product use is 200 C T4 indicates that the maximum surface temperature during product use is 135 C z T120 C T160 C It indicates that the maximum surface temper...

Страница 7: ...which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously or for long periods or frequently z Zone 21 a place in which an explosive atmosphere in the for...

Страница 8: ...oduct z Do not use a damaged antenna A minor burn may be caused when you touch a damaged antenna z Do not expose the product to direct sunlight for a long time nor place it close to a heating source z...

Страница 9: ...6 0 2015 FM Class 3611 2004 FM Class 3810 2005 FM Class 3600 2011 FM Class 3640 2013 FM Class 3610 2015 ANSI IEC 60529 Ed 4 0 2004 ANSI ISA 60079 0 12 00 01 Ed 6 0 2013 ANSI ISA 60079 11 12 02 01 Ed...

Страница 10: ...any item is missing or damaged please contact your dealer Radio Battery Charger Power Adapter Antenna Belt Clip Strap Documentation Kit Note The pictures in this manual are for reference only The freq...

Страница 11: ...o Part Name 1 SK1 Side Key 1 8 Power On Off Volume Control Knob 2 PTT Push to Talk Key 9 Microphone 3 SK2 Side Key 2 10 Accessory Connector 4 TK Top Key 11 Battery Latch 5 Channel Selector Knob 12 Ant...

Страница 12: ...press Emergency Off It is programmable by your dealer 3 3 LED Indicator LED Indication Radio Status The LED indicator flashes green Powering on The LED indicator glows green Receiving The LED indicato...

Страница 13: ...ry housing completely as shows Step 3 Push the battery until it is fully fitted into the slot and then release the battery latch as shows Note To remove the battery please power off the radio first Th...

Страница 14: ...g the Accessories Step 1 Open the accessory connector cover as shown below Step 2 Align the accessory such as an audio accessory or a programming cable plug with the accessory connector Caution Do not...

Страница 15: ...necessary safety information Charge a new battery for at least 5 hours before initial use for best performance Charging Status Indication on charger LED Indication Charging Status The LED Indicator fl...

Страница 16: ...your dealer And release the key to exit Battery power indications and alert tone are listed below LED Indication Tone Battery Power The LED Indicator glows green High The LED Indicator glows orange M...

Страница 17: ...with the same property which can facilitate convenient management over the channels The radio supports 3 zones each of which consists of up to 16 channels Your dealer can program the zone for your spe...

Страница 18: ...5 4 Selecting a Channel Note If the Channel Notify feature is enabled by your dealer the radio will announce the channel number upon channel switching...

Страница 19: ...your dealer to preset a regular private call contact for each digital channel 6 1 2 Receiving and Responding to a Private Call When you receive a private call you can listen to it without any operati...

Страница 20: ...ual along with the product for operation description on how to make and receive calls on the analog channel with signaling 6 4 Emergency Call In case of emergency you can use Emergency Call to ask for...

Страница 21: ...ce Services Group Call Private Call All Call z Control Services Alert Call Radio Check Remote Monitor Radio Enable Radio Disable Priority Interrupt Time out Timer TOT z Personal Security Services Emer...

Страница 22: ...ch the antenna The speaker may be blocked or damaged Clean the surface of the speaker You cannot communicate with other members The frequency or signaling may be inconsistent with that of other member...

Страница 23: ...n the underground areas Move to an open and flat area and restart the radio to try again You may suffer from external disturbance such as electromagnetic interference Stay away from equipment that may...

Страница 24: ...over when the accessory is not in use Product Cleaning Caution Turn off the product and remove the battery before cleaning z Clean up the dust and fine particles on the product surface and charging pi...

Страница 25: ...your local dealer for the optional accessories of the product Caution Use the accessories specified by the Company only otherwise the Company shall not be liable for any loss or damage arising out of...

Страница 26: ...n 3 Operating Temperature 30 C to 60 C non hazardous environment 20 C to 50 C hazardous environment Storage Temperature 40 C to 85 C Charging Temperature 0 C to 40 C Battery Ex battery BL1813 Ex 1800...

Отзывы: