The system requirements for the service computer are described in the related product
documents, refer to the following table.
Required product documents
Product
Document type
Described in
Service computer
Configuration Manual
Chapter 2
The service computer is connected via the connection panel. The ethernet interface
"SW1" is used by default for this purpose; with controller redundancy, the ethernet inter-
face "SW2" is additionally used for the connection to the second BSCU. During the con-
nection, the service computer is automatically assigned a local service IP address for the
respective DIB-R5 flexibleTx.
Connecting the service computer
Preparation:
n
The work equipment must be available, refer to
Chapter 4.3.1 “Work equipment for
n
The service computer must have been started.
n
The DIB-R5 flexibleTx must be switched on.
Figure 30: Connections of the service computer (local)
Connect the ethernet cable to the connector on the DIB-R5 flexibleTx (refer to
Figure 30) and to the ethernet port of the service computer.
➔
You have successfully connected the service computer.
4.3.3 Checking operating states
You can check manually whether the product and the hardware components installed
operate properly on the respective hardware component, if indicators are available, or via
a connected NMC-511 FaultManager network management client.
Operation
Function tests and operational monitoring > Checking operating states
DIB-R5 flexibleTx
67
Operation Manual 90DIBR5flexibleTxOM02 - 1.2