Technical Data 

 

 

SPT80A  

DIRECT DRIVE PUMP UNIT

 

230v - 80 LPM 

 

 

 

 

Please read carefully before commencing installation 

 

Registered Office: HYTEK (GB) LIMITED, Delta House, Green Street, Elsenham, Bishop’s Stortford 

CM22 6DS UK.  Registered in England No. 1915382 

Tel: +44 (0) 1279 815 600  Fax: +44 (0) 1279 812 978  email: [email protected]   

Web: www.hytekgb.com 

Содержание SPT80A

Страница 1: ...ase read carefully before commencing installation Registered Office HYTEK GB LIMITED Delta House Green Street Elsenham Bishop s Stortford CM22 6DS UK Registered in England No 1915382 Tel 44 0 1279 815 600 Fax 44 0 1279 812 978 email info hytekgb com Web www hytekgb com ...

Страница 2: ...se petrol or other flammable liquids 2 It must not be sited adjacent to a petrol dispenser or any other hazardous zone 3 On above ground storage tanks a spring loaded angle check valve or pressure regulating valve must be fitted at the tank outlet to prevent loss of fuel under gravity in the event of vandalism or accidental damage 4 Installation of this equipment and its associated tank pipe work ...

Страница 3: ...with a suitable thread sealing compound 4 Connect a suitable soft wall hose to the pump outlet In turn fit a suitable trigger or automatic nozzle onto the hose Seal both with a suitable thread sealing compound 5 Connect the flying lead to a suitable power supply fused at 10 amps for 230v AC and 16A for the 110v AC as follows 230v AC Brown Live Blue Neutral Yellow Green Earth 6 To prime the pump fi...

Страница 4: ...VE THE WARNINGS BELOW MAY LEAD TO THE PUMP UNIT BEING DAMAGED 1 Please ensure that the delivery hose is stowed correctly after each use to prevent it being run over by a vehicle 2 Do not run the pump dry 3 Do not run the pump for prolonged periods on bypass Nozzle closed Maximum running time on bypass 2 minutes 4 The supplied strainer or a suitable strainer filter MUST be fitted to the suction lin...

Страница 5: ...S559 5 DIMENSIONS ...

Страница 6: ...S LIST DIAGRAM No PART NUMBER DESCRIPTION 9 SPT80A 1 ROTOR 10 SPT80A 2 VANE 14 SPT80A 3 SHAFT KEY 16 SPT80A 4 ON OFF SWITCH 7 SPT80A 5 PUMP HOUSING 8 SPT80A 6 PUMP HOUSING O RING 20 SPT80A 7 SHAFT SEAL 17 SPT80A 17 JUNCTION BOX ...

Страница 7: ...S559 5 NOTES ...

Страница 8: ...1 2007 Immunity 2006 95 EC Electrical Equipment Low Voltage Machinery Directive 2006 42 EC The Pressure Equipment Regulations 1999 S I 1999 2001 Entry Into Force 29 November 1999 Amended to S I 2002 1267 Pressure Equipment Directive 97 23 EC Waste Electrical and Electronic Equipment Regulations 2006 2002 96 EC 2003 108 EC Authorized By Clive Wellings Technical Manager Hytek Declaration Number EC01...