S419/8
6. The FC20 and FC20.WM can switch the live supply of up to
two external pumps (220/240V AC, maximum 10 amps).
Connections are provided for this on the 220/240V terminal
block as shown in the wiring details diagram. The FC20.4 and
FC20.WM.4 can switch the live supply of up to two external
pumps.
7. Connect the external pulse supply, from up to two pumps,
inside the pulse connections junction box as shown in the
wiring details diagram. In the case of the FC20.WM the pulse
connection terminal block is located in the base of the cabinet.
An extra junction box/terminal block is provided for the FC20.4
and FC20.WM.4.
8. Ensure all the terminal screws are tight and replace the
junction box covers.
FC20 ELECTRICAL CONNECTION DETAILS
FC20 POWER
SUPPLY
(CONSTANT)
220 / 240V AC
FUSE - 16A
220 / 240 V AC
POWER
SUPPLY IN
E
L
N
1
3
2
5
E
4
7
6
8
FC20 & FC20.WM (2 PUMP) 220/240V TERMINAL BLOCK CONNECTIONS
EXTERNAL
PUMP
CONTROL
10
9
L
N
E
PUMP 2 LIVE
SUPPLY IN
PUMP 2 SWITCHED
LIVE SUPPLY OUT
PUMP 1 SWITCHED
LIVE SUPPLY OUT
PUMP 1 LIVE
SUPPLY IN
L
N
L
L
L
L