S858/4
SOLENOID
P/OUT
COM
GND
12V
PULSE IN
REED OPT
+12V
DC
CH
1
CH2 GND
GND IN 12V
NOZZLE
SWITCHES
GND SW GND SW GND SW
TANK
LEAK
EXT
GND
+
-
COMMS
5
6
4
2
1
3
0
V
-
B
L
A
C
K
(
W
&
M
B
R
O
W
N
)
A
N
D
S
C
R
N
10:1 /
100:1
PULSE
OUTPUT
PULSE
TRANSMITTER
INPUT
NOZZLE
SWITCH
INPUT
O
P
T
O
I
S
O
L
A
T
E
D
-
G
R
N
/Y
E
L
R
E
E
D
R
E
L
A
Y
-
B
L
U
E
C
O
M
M
O
N
-
B
R
O
W
N
G
R
E
E
N
/B
L
U
E
Y
E
L
L
O
W
+
1
2
V
D
C
-
R
E
D
(
W
&
M
G
R
E
E
N
)
C
H
1
-
Y
E
L
L
O
W
(
W
&
M
W
H
IT
E
)
C
H
2
-
G
R
E
E
N
(
W
&
M
Y
E
L
L
O
W
)
12V DC SOL.
OUTPUT
(WEIGHTS &
MEASURES
VERSION
ONLY)
0
V
-
B
L
U
E
+
1
2
V
D
C
-
B
R
O
W
N
R
E
D
2
1
3
2
1
2
1
3
2
1
3
4
2
1
3
LIVE
220/240 VAC
MOTOR RELAY
OUTPUT
1
1
2
3
2
220/240 VAC
POWER
INPUT
EARTH
LIVE - BLACK
NEUTRAL - GREY
NEUTRAL
AC INPUT
PUMP
DISPLAY /
CALCULATOR
VIEWED FROM
REAR
CALIBRATION
BUTTON
PUMP 2 DISPLAY CONNECTION DIAGRAM
INSTRUCTIONS FOR USE
1. See additional document for using the FC10 fuel control unit.
2. Remove the nozzle from the holster.
3. Place the nozzle spout in the fuel tank.
4. Squeeze the nozzle trigger to dispense fuel.
5. On completion of the delivery release the trigger and replace
the nozzle in the holster.