2000 SRM 1025
Valve Repair
5.
Connect the power wires to the lift pump motor
with the two nuts and washers. Torque the nuts
to 4.0 N•m (35 lbf in).
6.
Fill reservoir with hydraulic oil to proper level.
See Table 1.
7.
Connect battery and turn key switch to ON posi-
tion.
8.
Operate each hydraulic function several times to
purge the air from the hydraulic circuit.
9.
Check the top of the lift cylinder to determine if
a buttonhead bleed screw is present. If a bleed
screw is present, bleed the air from the hydraulic
system. See Bleed Hydraulic System.
10. Check hydraulic oil level in reservoir and fill to
proper level. See Table 1.
11. Test lift truck by lifting and lowering a load sev-
eral times. Check for leaks.
12. Install the drive unit compartment cover. If nec-
essary, install the hydraulic unit compartment
cover.
Valve Repair
PROPORTIONAL VALVE (LOWERING)
Remove
1.
Move lift truck to a safe and level area.
2.
Lower the forks completely to relieve pressure
from the hydraulic system.
3.
Turn key switch to OFF position and disconnect
battery.
4.
Block load wheels to prevent lift truck from mov-
ing. Refer to Periodic Maintenance 8000 SRM
1027.
5.
Remove the drive unit compartment cover. On
W25/30/40ZC lift trucks, also remove the hy-
draulic compartment cover.
6.
Discharge the capacitor.
See Special Precau-
tions.
WARNING
Hydraulic oil hoses and lines may be under
high pressure. Hydraulic oil can be injected
into the body by pressure. To prevent possible
injury, shield yourself from any escaping oil.
Wrap a rag around the fitting and loosen the
fitting and loosen the connection slowly.
CAUTION
To prevent dirt or contaminants from entering
the hydraulic system, always install caps on
the hoses and ports of the pump.
7.
Tag and disconnect any power wires or hydraulic
hoses blocking access to the valve.
8.
Remove the locking screw from the control wiring
plug. Disconnect the plug from the coil.
9.
Remove the retaining clip and washer.
10. Slide the coil off of the valve.
11. Remove the valve cartridge.
Install
1.
Verify that the O-rings on the valve cartridge are
not damaged. Replace as needed.
2.
Verify that the valve cartridge and valve block
are clean and not damaged.
3.
Lubricate the valve cartridge threads and
O-rings with clean hydraulic oil.
4.
Install the valve cartridge and torque to 27 N•m
(20 lbf ft).
5.
Slide the coil onto the valve cartridge with the
lettering out towards the coil retainer.
6.
Install the washer and retaining clip.
7.
Connect any power wires and hydraulic hoses
previously disconnected.
8.
Connect the control wiring plug to the coil.
9.
Install the locking screw into the coil plug.
10. Connect battery and turn key switch to ON posi-
tion.
13
Содержание W20-30ZR
Страница 9: ...2000 SRM 1025 Manual Lowering Figure 2 Single Function Manual Lowering Screw Top View 5...
Страница 34: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 30...
Страница 35: ...2000 SRM 1025 Hydraulic Diagrams and Schematics Figure 17 Hydraulic Schematic W30 40ZA Without Side shift 31...
Страница 36: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 32...
Страница 37: ...2000 SRM 1025 Hydraulic Diagrams and Schematics Figure 18 Hydraulic Schematic W30 40ZA With Side shift 33...
Страница 38: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 34...
Страница 39: ...2000 SRM 1025 Hydraulic Diagrams and Schematics Figure 19 Hydraulic Schematic W20 30ZR Without Side shift 35...
Страница 40: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 36...
Страница 41: ...2000 SRM 1025 Hydraulic Diagrams and Schematics Figure 20 Hydraulic Schematic W20 30ZR With Side shift 37...
Страница 42: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 38...
Страница 43: ...2000 SRM 1025 Hydraulic Diagrams and Schematics Figure 21 Hydraulic Schematic W25 30 40ZC With Side shift 39...
Страница 44: ...Hydraulic Diagrams and Schematics 2000 SRM 1025 40...
Страница 47: ......
Страница 48: ...TECHNICAL PUBLICATIONS 2000 SRM 1025 5 03 4 03 2 03 Printed in U S A...