P1.6 Lift Speed
This parameter allows the user to adjust the mast
lift speed from the maximum lift speed to some
lower speed within the parameter range. The set-
ting range is from 1 to 9. Setting this parameter to
“9” will result in maximum lift speed. Setting this
parameter to “1” will result in minimum lift speed.
P1.7 Lower Speed
This parameter allows the user to adjust the mast
lower speed from the maximum lower speed to
some lower speed within the parameter range. The
setting range is from 1 to 9. Setting this parameter
to “9” will result in maximum lower speed. Setting
this parameter to “1” will result in minimum lower
speed.
P1.8 Lift Accel
This parameter allows the user to adjust the hy-
draulic pump motor acceleration during lifting from
the maximum acceleration rate to some lower accel-
eration rate within the parameter range. The set-
ting range is from 1 to 9. Setting this parameter to
“9” will result in maximum acceleration during lift-
ing. Setting this parameter to “1” will result in min-
imum acceleration during lifting.
P1.9 Lift Decel
This parameter allows the user to adjust the hy-
draulic pump motor deceleration during lifting
from the maximum deceleration rate to some lower
deceleration rate within the parameter range. The
setting range is from 1 to 9. Setting this parameter
to “9” will result in maximum deceleration during
lifting. Setting this parameter to “1” will result in
minimum deceleration during lifting.
P1.10 Lower Accel
This parameter allows the user to adjust solenoid
acceleration while lowering from the maximum ac-
celeration rate to some lower acceleration rate
within the parameter range. The setting range is
from 1 to 9. Setting this parameter to “9” will result
in maximum acceleration during lowering. Setting
this parameter to “1” will result in minimum accel-
eration during lowering.
P1.11 Lower Decel
This parameter allows the user to adjust solenoid
deceleration while lowering from the maximum de-
celeration rate to some lower deceleration rate
within the parameter range. The setting range is
from 1 to 9. Setting this parameter to “9” will result
in maximum deceleration during lowering. Setting
this parameter to “1” will result in minimum decel-
eration during lowering.
P1.12 Tilt Speed Main
This parameter is used to adjust tilt speed when
the mast is elevated above free lift. It also controls
tilt speed when the mast is below free lift if the
truck is NOT equipped with "Reduced Speed Tilt"
option.
P1.13 Tilt Speed Free
This parameter allows the user to adjust the maxi-
mum tilt speed when the mast is raised above free-
lift position. The setting range is from 1 to 9. Set-
ting this parameter to “9” will result in maximum
tilt speed. Setting this parameter to “1” will result
in minimum tilt speed.
P1.14 Tilt Accel
This parameter allows the user to adjust the rate of
tilt speed acceleration. The setting range is from 1
to 9. Setting this parameter to “9” will result in
maximum accel speed. Setting this parameter to
“1” will result in minimum accel speed.
P1.15 Tilt Decel
This parameter allows the user to adjust the rate of
tilt speed deceleration. The setting range is from 1
to 9. Setting this parameter to “9” will result in
maximum decel speed. Setting this parameter to
“1” will result in minimum decel speed.
P1.16 Sideshift Speed Main
This parameter allows the user to adjust the maxi-
mum sideshift speed. The setting range is from 1 to
9. Setting this parameter to “9” will result in maxi-
mum sideshift speed. Setting this parameter to “1”
will result in minimum sideshift speed.
2200 SRM 2023