background image

H1 Truck Hours

The  Truck  Hours  hourmeter  accumulates  time
when the key switch is in the ON position and the
operator presence switch is activated.

H2 Traction Hours

The  Traction  Hours  hourmeter  accumulates  time
when the traction motor is activated.

H3 Pump Hours

The  Pump  Hours  hourmeter  accumulates  time
when the lift motor is activated.

H4 Steer Hours

The  Steer  Hours  hourmeter  accumulates  time
when the steer motor is activated.

H5 Odometer Hours

The  Odometer  Hours  hourmeter  shows  the  total
number  of  miles/kilometers  driven  based  on  the
traction hours.

H10 Display Hours

The Display Hours hourmeter shows the total num-
ber of hours of operation of the display.

H30 Traction Node Hours

The  Traction  Hours  hourmeter  shows  the  total
number  of  hours  of  operation  of  the  traction  con-
troller.

H41 Slave Traction Node Hours

The Steer Hours hourmeter shows the total number
of hours of operation of the steer controller.

H50 Pump Node Hours

The  Pump  Hours  hourmeter  shows  the  total  num-
ber of hours of operation of the pump controller.

PERFORMANCE

The lift truck software allows for the setting of four
independent performance levels. See Table 4. When
the  password  setting  is  enabled,  specific  levels  of
lift truck performance can be specified for any oper-

ator  with  a  valid  password  for  this  lift  truck.  Lift
truck performance levels can only be set or altered
by  a  supervisor  or  technician.  Scroll  through  the
Performance  Level  menu  using  the  UP  (#1)  and
DOWN (#3) buttons and press the RIGHT (#2) but-
ton  to  enter  the  desired  selection.  Press  the  LEFT
(#4) button to return to the previous menu.

Table 4.  Performance-Level Menu 

PERFORMANCE

Press 

Button

P1

PERFORMANCE 1

P2

PERFORMANCE 2

P3

PERFORMANCE 3

P4

PERFORMANCE 4

Supervisor-Level Menu

2200 SRM 2023

6

Содержание C219

Страница 1: ...Hyster C219 E30HSD3 E35HSD3 E40HSD3 Forklift...

Страница 2: ...USER INTERFACE SUPERVISOR E30HSD3 E35HSD3 E40HSD3 C219 PART NO 4131296 2200 SRM 2023...

Страница 3: ...dic Maintenance section Keep the unit clean and the working area clean and orderly Use the correct tools for the job Keep the tools clean and in good condition Always use HYSTER APPROVED parts when ma...

Страница 4: ...ction Node Hours 6 H50 Pump Node Hours 6 Performance 6 Performance Level 1 7 P1 1 Forward 8 P1 2 Reverse 8 P1 3 Acceleration 8 P1 4 Plug 8 P1 5 Coast 8 P1 6 Lift Speed 9 P1 7 Lower Speed 9 P1 8 Lift A...

Страница 5: ...ore information Please click here Then get the complete manual NOTE If there is no response to click on the link above please download the PDF document first and then click on it Have any questions pl...

Страница 6: ...TENTS Continued Operator 1 150 11 Information 12 I1 Model 12 I3 Serial Number 12 I5 Truck Voltage 12 Software Versions 13 This section is for the following models E30HSD3 E35HSD3 E40HSD3 C219 Table of...

Страница 7: ...ust be performed by a service technician accessing the menu system with a service level password The supervisor password must be set up before a supervisor can access the menu functions The dash displ...

Страница 8: ...en Menu navigation is accomplished by using the display buttons From inside the menu the buttons function as follows 1 UP Scroll up within a menu or increase the value of a setting when making a param...

Страница 9: ...uttons to navi gate to the menu item allowed for your password level Use the LEFT 4 and RIGHT 2 buttons to move within the selected menu Use the CEN TER 5 button to confirm your selections Table 1 Pas...

Страница 10: ...With a proper Supervisor level password a supervisor can access menu items that are not visible at Operator level access See Table 2 See Table 1 for the submenu choices available at the Service Level...

Страница 11: ...tions See Table 3 Scroll through the Hour Meters menu using the UP 1 and DOWN 3 buttons and press the RIGHT 2 button to enter the desired selection Press the LEFT 4 button to return to the previous me...

Страница 12: ...raction con troller H41 Slave Traction Node Hours The Steer Hours hourmeter shows the total number of hours of operation of the steer controller H50 Pump Node Hours The Pump Hours hourmeter shows the...

Страница 13: ...1 PERFORMANCE 1 Press Button P1 1 FORWARD P1 2 REVERSE P1 3 ACCELERATION P1 4 PLUG P1 5 COAST P1 6 LIFT SPEED P1 7 LOWER SPEED P1 8 LIFT ACCEL P1 9 LIFT DECEL P1 10 LOWER ACCEL P1 11 LOWER DECEL P1 12...

Страница 14: ...rameters to the minimum value in the parameter value range The setting range is from 1 to 9 Setting this parameter to 9 will result in maximum acceleration Setting this parameter to 1 will result in m...

Страница 15: ...meter to 9 will result in maximum acceleration during lowering Setting this parameter to 1 will result in minimum accel eration during lowering P1 11 Lower Decel This parameter allows the user to adju...

Страница 16: ...the desired selection Press the LEFT 4 button to return to the previ ous menu Password In the password display you are allowed a five digit password utilizing the numbers 1 through 5 zero is not a va...

Страница 17: ...this screen to turn the operator password fea ture ON or OFF Clear Log Use this screen to clear all stored information from the operator log OPERATOR LOGS An operator log is created when a new user pa...

Страница 18: ...Information Menu INFORMATION Press Button I1 MODEL I3 SERIAL NUMBER I5 TRUCK VOLTAGE I1 Model The Model parameter displays the model of the lift truck and does not have any functions It is for in form...

Страница 19: ...ion This truck auto matically coordinates the software of all nodes One software version number is used to indicate the to tal truck software Table 9 Software Versions SOFTWARE VERSIONS Press Button V...

Страница 20: ...NOTES 14...

Страница 21: ......

Отзывы: