Main Control Valve, Section 2 of Hydraulic Plate
2000 SRM 1233
5.
Remove O-rings installed between the auxiliary
section and lift section.
Lift Section
CAUTION
Make sure to protect machined surfaces for
O-rings when the sections are separated. Small
defects can cause leaks.
1.
Place the main control valve on a clean and level
surface.
2.
Disassemble the auxiliary section. See Auxiliary
Section.
3.
Loosen the four nuts. See Figure 10 and Fig-
ure 11.
4.
Carefully remove the four nuts and bolts.
5.
Carefully slide the lift section from the lift/tilt
section.
6.
Remove O-rings installed between the lift section
and lift/tilt section.
Figure 10. Main Control Valve Section (Single Spool for Lift)
12