STOP BUTTON

OPEN BUTTON

CLOSE BUTTON

REMOTE OPEN AND

RADIO CONTROL

OPEN/CLOSE

1

OPEN PARTIAL

INTERLOCK OPEN

TIME CLOCK OPEN

FREE EXIT DETECTOR

DISABLE EXIT DETECTOR

DISABLE CLOSE TIMER

INSIDE OBSTRUCTION

VEHICLE DETECTOR
OUTSIDE OBSTRUCTION

VEHICLE DETECTOR

SHADOW/RESET

VEHICLE DETECTOR

SENSOR 1

SENSOR COM

DO NOT USE

DO NOT USE

DO NOT USE

CHARGER

AC LOSS 

LOCK INTERLOCK

EMERG CLOSE

FIRE DEPT OPEN

2

3

4

5

6

7

8

9

10

11

12

14

15

16

17

18

19

20

21

22

23

24

Smart Touch Controller

LIMIT

DUAL GATE

RADIO OPTIONS

DRIVE

POWER

RS485

MO
TOR

USER 1

USER 2

USER 3

VEHICLE DETE

CT

OR

VEHICLE DETE

CT

OR

VEHICLE DETE

CT

OR

ST

OP

/B

UZZER

FREE

EXIT

INSIDE

OBS
TR

OUT
SIDE

OBS
TR

SHADO

W

RE

SET

WI

EGAND

Hy

Security

COM

NO

MX000585

VERSION

S/N

RS232

DISPLA

Y

VEHICLE DETE

CT

OR

COM

COM

A

B

RPM

COM

OPEN

S 1

+24V

+24V

STATUS

LED

24V A

C  Ac

cessor

y pow

er

+ 24

V D

C

COM

MO

N

+ 24VDC

Inputs

SENSOR 2

SENSOR 3

Smart Touch Controller

RS-485 
Connector

Menu 
button

Select 
button

Reset 
button

Open 
button

SA 1 
SYSTEM ADDRESS

Press Select again to set gate operator's system 
address (Each gate operator attached to the 
same HyNet must have a unique SA number. 
Choose 1, 2, 3, or 4.)

2

1

To access Installer Menu, press Menu button 
twice. Then, press Reset and Open.
Press Select to navigate to Installer Menu item 
"SA" System Address.

3

To exit Menu mode, press Menu. The gate 
operator returns to Run mode.

4

Refer to 

Table 1: HyNet LED Indicators

 on page 

2. Solid green means serial communication 
is active and functioning well.

HySecurity gate operators provides a 2-wire, serial interface (RS-485 connection) which allows remote access to 

one or more operators.

When the physical connection is made and protocols are established, an SA (System Address) must be assigned 
for each operator through its Installer Menu. 

For network communication, choosing a “SA” of 1 to 4 establishes individual network polling addresses. HyNet 
only utilizes numbers 1, 2, 3, or 4.

A “SA” of zero means no network communication is desired.

5

For IP network setup, refer to the HyNet Quick 
Start manual supplied in the HyNet box..

Power Supply Board

Tact 
button

+24VDC Accessory Power (+)

Common Bus (-)

www.SecureOpeners.com  |  (800) 878-7829  |  [email protected]

Содержание SlideDriver 15

Страница 1: ...emental document that provides specific information regarding configuration of the HySecurity gate operator with installation and wiring of the HyNet Gateway For safety considerations and information...

Страница 2: ...or and HyNet 2 RED steady Gate operator network communication is not configured or established 2 RED flashing HyNet is attempting to connect to network web interface 2 GREEN flashing Network web inter...

Страница 3: ...4x HyNet Assembly for SlideDriver and StrongArm Alcohol wipe Use alcohol wipe to clean mounting plate surface before applying Velcro adhesive backing Velcro strip Adhere to gate operator chassis HyNe...

Страница 4: ...Recommended HyNet location is shown in the illustration Ambient temperature for adhesion is between 45 and 85 F 4 Set the HyNet onto the chassis so the ports are accessible as shown in the illustratio...

Страница 5: ...he StrongArm chassis Press firmly NOTE Recommended HyNet location is shown in the illustration Ambient temperature for adhesion is between 45 and 85 F 4 Set the HyNet onto the chassis shelf so the por...

Страница 6: ...HySecurity COM NO MX000585 VERSION S N RS232 DISPLAY VEHICLE DETECTOR COM COM A B RPM COM OPEN S 1 24V 24V STATUS LED 24V AC Accessory power 24V DC COMMON 24VDC Inputs SENSOR 2 SENSOR 3 Pin 1 24V DO...

Страница 7: ...SS Press Select again to set gate operator s system address Each gate operator attached to the same HyNet must have a unique SA number Choose 1 2 3 or 4 2 1 To access Installer Menu press Menu button...

Страница 8: ..._______________ Phone contact number ____________________________________ Checked Initials 1 Site Planning ______________ RJ 45 cable to system network 2 Safety ______________ Review Important Safety...

Отзывы: