HyQuest Solutions Pty Ltd
Tipping Bucket Flow Gauge
TB1L 100-08 Issue 1:26/9/2016
VII.
ELECTRICAL
Dual reed switches are provided for several reasons:
Two isolated switches permit the control of two separate circuits; e.g. a
local counter and a telemetry circuit.
Parallel connection of both switches increases the current carrying
capacity of the contact system if required.
Parallel switch operation confers a degree of redundancy in locations
where data from the Flow Gauge is critical to flood warning etc.
Note: 2x Digital inputs with maximum capacity of
24 Volts (0.5amp max.). They operate
simultaneously to two different RTU’s (example Data logger & Satellite modem)
DIAGRAM 4
Input 1
Input 2