HyQual Multi-probes User Manual v3, 08.07.2022 
KISTERS Controlled, Template: Word-with-table-of-contents-Template-Company.docx, v1.1 

Page 5 / 23 

 

 

Scope of Delivery

 

1x either HyQual 200 or HyQual 300 or HyQual 300T multi-probe 
1x non-vented underwater cable (5, 10, 20, 30, 40 and 50 m)  

Temperature sensor, dissolved oxygen sensor, specific conductivity sensor, pH

 sensor and ORP sensor 

1x weighted sensor guard 
1x kit: tool and maintenance 
1x Internal memory  
 3-year warranty 
Only for HyQual 300T: Turbidity sensor and its wiper 
Interface RS-232 
Soft carrying case 

… and any option ordered with the 

 multi-probe 

 

1.1

 

Required Accessories 

 

Power supply 

 

HyQual probes require a source of power.  
 
Choices of power supply out of the water:  
 

 

For spot measurements, the optional external rechargeable Bluetooth® wireless technology bat-
tery enclosed in a waterproof (IP67) case connects to the probe via the 

HyQual probe‘s standard 

underwater cable running RS-232 or SDI-12. This battery operates only at the surface and its job 

is to power the multiprobe while you’re pairing the instrument with a data display via 

Bluetooth

® wireless technology. 

 

 

A USB port on a PC is another way of suppling power to the multi-probes. For this case you 
would need to add the optional USB adapter. 

 

 

HyQual also connects to third-party devices (data loggers, samplers, telemetry, etc.) that supply 
power. 

 
Choices of power supply that operate underwater: 
 

 

Instead of using power from the underwater cable you could use the optional EBP external re-

chargeable battery pack. This battery is ideal for HyQual 300 and 300 T due to its 75 mm (3 “) 

diameter. It also works fine with the 200 version, only it makes it look top heavy. Use the EBP 
external battery pack when you do not wish to have downtimes of charging the battery. The EPB 
is removable so you can replace it with a freshly charged battery right in the field. Please note 
that the use of EBP adds several millimeters to the length of the multiprobe. 

 
 

Communication and connection 

 

Available for the HyQual probes is an optional SDI-12 and ModBus interface, with either an SDI-12 or 
MODBUS adapter cable. 

Содержание HyQual

Страница 1: ...HyQual Water Quality Multi Probe HyQuest Solutions KISTERS Group 2022 05 03...

Страница 2: ...ction 10 6 2 2 Unattended Logging 10 6 2 3 Telemetry Relay 11 6 2 4 On Line Monitoring 12 7 1 When to proceed to maintenance 12 7 2 Maintenance 1 Keep your device clean 12 7 3 Maintenance 1 Calibratio...

Страница 3: ...ilidad de tales da os Cualquier error encontrado en cualquier producto de HyQuest Solutions debe ser comuni cado a HyQuest Solutions donde se har todo lo posible para resolver r pidamente el pro blema...

Страница 4: ...industrial specification that defines the electrical interface and physical layer for point to point communication of electrical devices The RS 485 stand ard allows for long cabling distances in elec...

Страница 5: ...s battery operates only at the surface and its job is to power the multiprobe while you re pairing the instrument with a data display via Bluetooth wireless technology A USB port on a PC is another wa...

Страница 6: ...send the probe back to us at your own expense Additional sensors Barometric pressure is calculated with the use of the depth sensor therefore you will need to add an optional depth sensor to any of yo...

Страница 7: ...ufacturer s named repair center You can find information on how to re turn items for repair in the relevant section of the HyQuest Solutions website Disposal instructions After taking any HyQuest Solu...

Страница 8: ...ufficient water flow that can be easily ac cessed for maintenance and protected from external elements such as animals and items such as stones or sticks that may damage the probe 4 1 Protection for u...

Страница 9: ...n to toggle between Logging ON and Logging OFF The Setup function for Logging lets you name your Logging file and set the logging interval time be tween logged lines of data Figure 1 Switch Logging ON...

Страница 10: ...The Display can be a laptop or almost any tablet or smart phone You can record measurements using the HyQual probe s Snapshot or Automatic Snapshot features You might snapshot a series of measurements...

Страница 11: ...rchase this battery after as it is not integrated to the probe Please note that this battery ads several inches to the length of the probe and that it can also be used with the HyQual 200 only that it...

Страница 12: ...ed in the control loop or decision making process Maintenance 7 1 When to proceed to maintenance Judgment gained from observing your field conditions and data requirements provides information about w...

Страница 13: ...tuation for which the correct parameter value is known Here s the general procedure 1 Clean the sensor and perform any necessary sensor specific maintenance 2 Select a calibration standard whose value...

Страница 14: ...c But you can elect to accept any SRF 7 3 3 Choosing Calibration Standards For best results choose a calibration standard whose value is close to what you expect to see in the field For example calibr...

Страница 15: ...ate of the calibration the parameter calibrated the reading before the calibration was accepted the read ing after the calibration was accepted the raw sensor reading the SRF and a few other details I...

Страница 16: ...follow the calibration instructions on the screen The manufacturers of optical DO sensors usually recommend that you not calibrate the zero DO point because the zero DO point drift is very low However...

Страница 17: ...don t report because it has little meaning in natural waters You can t calibrate TDS or salinity directly because they are calculated from Conductivity You can however calibrate TDS with a TDS standar...

Страница 18: ...ous circle at the end of the sleeve This not only purges bubbles from the electrolyte but also cleans nasty stuff out of the junction Figure 4 Filling in fresh pH reference electrolyte 7 3 10 ORP ORP...

Страница 19: ...s a small hole in the back of the transducer There is a tube inside the cable i e a Vented Cable to connect the Stage sensor to the atmosphere so that changes in barometric pressure will not affect t...

Страница 20: ...e small set screw on the wiper arm 2 Remove the wiper pad from the wiper arm and replace the pad 3 Place a new wiper arm on the motor shaft so that the set screw faces the flat spot on the motor shaft...

Страница 21: ...bor charge 1 2 days down time Repair HyQuest Solutions precision instruments and data loggers are produced in quality controlled processes All HyQuest Solutions production and assembly sites in Austra...

Страница 22: ...lay devices not for eld use calibration solutions copper anti fouling kit USB adapter connect DB9 to USB inte grated SDI 12 and MODBUS output SDI 12 adapter cable MODBUS adapter cable and Android disp...

Страница 23: ...ion battery must be dis posed of according to legal provisions EU WEEE Directive As players in the environmental market KISTERS AG and HyQuest Solutions are committed to supporting efforts to avoid a...

Отзывы: