Gear
1-3/8" Male
1 3/8" Female Shaft
Reduction
Hydraulic
Splined PTO 1" Solid Shaft w/ Torque Arm Bracket
Units for Gas
Motor Mounting
Shaft
W/Keyway
for PTO Drive
Engine Drive
Flange KIt
- 2 -
CONTROL
MAX
MAX
PUMP
UNIT MODEL
GPM
PSI
MODEL
9910-GS50GI
48
725
ALL MODELS
9910-VDR50
35
725
-D813, -D1064,
and -D1265
Order the appropriate shaft adapter kit or gear reduction unit for the drive option requirements. Refer to the chart below
for proper selection. For proper installation of the gear reducer, refer to the installation instructions.
Pump
Model
Drive Options
Control Units
Control units are available for easy flow and pressure
control of your sprayer system. These units include a
pressure relief valve to control pressure, an oil-filled
pressure gauge to monitor pressure, and outlet ball
valves to control flow. Control Unit 9910-GS50GI can
be remote mounted with Kit No. 9910-KIT1742.
No additional kit is required for remote mounting
Control Unit 9910-VDR50. Refer to the adjoining
chart to select the proper control unit for your pump.
General Safety Information
9910-D813
9910-KIT2200 9910-KIT2203
9910-KIT2204
9910-KIT1642 for 8-18 hp 9910-KIT5312
9910-D1064
9910-KIT2200 9910-KIT2203
9910-KIT2204
9910-KIT1642 for 8-18 hp 9910-KIT5312
9910-D1265
9910-KIT2200 9910-KIT2203
9910-KIT2204
9910-KIT1642 for 8-18 hp 9910-KIT5312
9910-D1516
N/A
N/A
N/A
N/A
N/A
Form L-1383 (12/11, Rev. B)
1. Use of a pressure relief device on the discharge
side of pump is required to prevent damage from
pressure build up if the discharge is closed or blocked
while the power source is still running.
2. WARNING: DO NOT pump flammable or explosive
fluids such as gasoline, fuel oil, kerosene, etc. DO
NOT use in explosive atmospheres. The pump
should be used only with liquids that are
compatible with the pump component materials.
DO NOT pump asphalt, asphalt sealer, roofing
compounds, concrete sealers or any two-step
curing products. Personal injury may result, and
the warranty will be void. If there are any
questions, call the Hypro Applications toll-free
number: 800-445-8360.
3. Do not operate the pump above the recommended
rpm.
4. Do not pump at pressures higher than the
maximum recommended pressures for the
pump (see Specifications).
5. Operate the pump between temperature ranges of
45o to 140o F.
6. Make certain that the power source conforms to the
requirements of your equipment.
7. Provide adequate protection for guarding around the
moving parts such as the shaft and pulleys.
8. Disconnect the power before servicing.
9. Release all pressure within the system before
servicing any component.
10. Drain all liquids from the system before servicing.
11. Secure the discharge lines before starting the pump.
An unsecured discharge line may whip, causing
personal injury and/or property damage.
12. Check the hoses for weak or worn condition before
each use. Make certain that all connections are tight
and secure.
13. Periodically inspect the pump and the system
components. Perform routine maintenance as
required (see Maintenance section).
14. When wiring an electrically-driven pump, follow all
electrical and safety codes, as well as the most recent
National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
Содержание 9910-D1064
Страница 22: ...22 NOTES Form L 1383 12 11 Rev B...
Страница 23: ...23 NOTES Form L 1383 12 11 Rev B...