15 HPT USER MANUAL
Please refer to
EASTRON SDM630-Modbus V2 User manual
for its connection and
baud rate settings.
6.3 Demand Responsive Modes(DRMs)
The inverter shall detect and initiate a response to all supported demand response
commands.
MODE
DEMAND
DRM 0
Disconnect
DRM 1
No power consumption
DRM 2
Power consumption <50% rated power
DRM 3
Power consumption <75% rated power AND respond to reactive power when
capable
DRM 4
Increase power consumption (prior subject to constraints from other active DRMs)
DRM 5
No power generation
DRM 6
Power generation <50% rated power
DRM 7
Power generation <75% rated power AND sink reactive power if possible
DRM 8
Increase power generation (prior subject to constraints from other active DRMs)
DRMs Application Description
•
Only applicable to AS/NZS4777.2:2015.