![Hypertherm Powermax 30 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/hypertherm/powermax-30/powermax-30_service-manual_2193827053.webp)
MAINTENANCE
3-14
powermax30
Service Manual
System tests
There is a ground clip near the top of the rear endcap that can be used as ground for any tests that require the
multimeter to be attached to ground. There is also a ground on the heat sink with access through the power board
as shown in test 1.
Error LED
The number of times the Error LED flashes indicates the problem detected. Each flash is a half-second long and
each series of flashes is separated by a 2-second pause. See
System tests, later in this section, for detailed test
procedures.
Number of error
LED flashes
Problem indicated
Solution
1
Faulty control board
Replace the control board.
2
Faulty power board
Replace the power board.
3
Either a faulty power board
or a faulty control board
• Perform test 3. If any of the values are incorrect, replace
the power board.
• Perform test 2. If any of the values for pins 5, 7, or 12 are
incorrect, remove the control board and test again. If the
values are correct, replace the control board.
• When performing test 2, if the values for pins 5, 7, and 12
are correct, but any other values are incorrect, replace
the power board.
4
Faulty gas solenoid valve
Replace the gas solenoid valve.
5
Faulty fan
Replace the fan.
Ground wire clip
Содержание Powermax 30
Страница 1: ...Plasma arc cutting system Service Manual 805170 Revision 2 ...
Страница 11: ...TABLE OF CONTENTS viii powermax30 Service Manual ...
Страница 77: ...MAINTENANCE 3 38 powermax30 Service Manual ...
Страница 85: ...PARTS 4 8 powermax30 Service Manual ...
Страница 86: ...powermax30 Service Manual 5 1 Section 5 WIRING DIAGRAM In this section Electrical schematic 5 3 ...
Страница 87: ...WIRING DIAGRAM 5 2 powermax30 Service Manual ...