Rated Open Circuit Voltage (U
0
)
300 VDC
Output Characteristic*
Drooping
*Defined as a plot of output voltage
versus output current
Rated Output Current (I
2
)
30A – 100A
Hypertherm Standard Rated Output
160 VDC
Voltage (U
2
)
Duty Cycle (X*) at 104°F (40°C) at
U
1
– Volts AC rms
X
rated conditions (U
1
, I
1
, U
2
, I
2
)
200-208 VAC 3PH
60%
230-240 VAC 3PH
70%
*X = T
on
/T
base
,
380-415 VAC 3PH
80%
T
on
= time, minutes
480 VAC 3PH
80%
T
base
= 10 minutes
600 VAC 3PH
80%
Operating temperature
14
o
to 104
o
F (-10
o
to 40
o
C)
Rated AC phases (PH) and line frequency (Hz)
PH
Hz
Standard and CE Model
3
50-60
Rated Input Voltage (U
1
), rated Input
U
1
– Volts AC rms
I
1
-Amps rms
I
1
eff
Current (I
1
) and I
1
eff* at rated Output
200-208 VAC 3PH
53
41
U
2
and I
2
– cutting only.
230-240 VAC 3PH
46
38
380-415 VAC 3PH
27
24
*I
1
eff = (I
1
) X used to determine
480 VAC 3PH
22
20
rating of power cord.
600 VAC 3PH
21
19
U
1
– Volts AC rms
Harmonic
Displacement
Power Factor
Power Factor
Power Factor
200-208 VAC 3PH
0.94
0.98
230-240 VAC 3PH
0.94
0.98
380-415 VAC 3PH
0.94
0.99
480 VAC 3PH
0.94
0.99
600 VAC 3PH
0.78
0.99
R
sce
– Short Circuit Ratio—CE Model only
U
1
– Volts AC rms, 3PH
R
sce
400 VAC
191
230 VAC
142
This equipment conforms to IEC 61000-3-12,
provided that R
sce min
= 191 at 400VAC 3PH
and 142 at 230 VAC 3PH.
IP code—Degree of protection
IP23CS*
provided by enclosure
IP – “International Protection”
2 – No ingress foreign objects
>
=12.5mm (0.5 in)
3 – No harmful ingress spraying water
C – AC line circuits protected against ingress of
tool
>
=2.5 mm dia. x 100 mm long
(0.1 inch x 4.0 inch)
S – fan stationary during water test
*WARNING: DO NOT OPERATE IN RAIN
Toppling, Tilting (with or without wheel kit)
Up to 15
o
incline
.
Gas Type
Air
Nitrogen
Gas Quality
Clean, moisture-free, oil-free
Gas Inlet Pressure and Flow
90-120 psig (6.2-8.3 bar) 550 scfh/9.2 scfm (260 l/min)
2-2
powermax1650
Service Manual
SPECIFICATIONS
0
Specifications – Power Supply
Содержание Powermax 1650
Страница 27: ...2 8 powermax1650 Service Manual SPECIFICATIONS 0 ...
Страница 61: ...PARTS POWER SUPPLY 4 8 powermax1650 Service Manual 0 ...
Страница 64: ...PARTS TORCH AND CONSUMABLES powermax1650 Service Manual 5 3 0 ...
Страница 66: ...PARTS TORCH AND CONSUMABLES powermax1650 Service Manual 5 5 0 ...