Automated Plasma Interface
458
Multiple Supplies
The Serial Communication Link supported by the CNC can also be extended to multiple power
supplies.
This unique feature is implemented through the use of the serial link and I/O points. It is assumed
that the all systems are configured similarly and will be used simultaneously. If any of the selected
power supplies has a fault, the fault must be cleared before the cut can begin.
Specific hardware and software versions for both the control and the power supply are required.
Please refer to the power supply manual for additional information on operation and installation.
Inputs and Outputs
Raise 1-4 and Lower 1-4
The Raise / Lower inputs will be used to control the Integrated Command™ THC lifters on multi-
dropped supplies for the selected process.
Note: When using this feature with the Sensor™ THCs rather than the Integrated Command™ THCs,
the Sensor™ THC Torch Raise and Torch Lower commands for the selected process may be made
through the software softkeys or through the use of these external inputs to the control.
Cut Sense 1-4
THC Cut Sense Input (arc on feedback) is used to verify that the plasma torch or marker tool has
established the arc for the selected torch. This indicates to the control that motion can begin.
Ready to Fire PS 1-4
This signal is an output from each supply and is used in multiple plasma systems. It notifies the CNC
that the THC has completed the IHS cycle and Preflow is complete. This indicates that the torch is
ready to fire. On the supply this signal is used along with the CNC Plasma Sync Input. The CNC Hold
Ignition output is connected to the supply “CNC Plasma Sync” inputs. When all configured supplies
return active “Ready to Fire” signals, the “Hold Ignition” signals are removed.
Hold Ignition
The Hold Ignition Output is used to delay ignition of the external plasma supply and allow the
individual supplies to complete Preflow and IHS before torch ignition. For this application, the Hold
Ignition would be tied to the Plasma Sync Inputs for multi-dropped supplies.
Reduce Current
Used with the supply to switch the plasma to low current mode. This signal is functionally different
from the Torch Height Disable Output in that it is not active during the initial torch ignition, pierce, and
accelerate to speed after Plasma Start. For this application, the Reduced Current output would be
tied to the Corner Hold Inputs for multi-dropped power supplies.
The Corner Current Parameter located on the Plasma Setup Screen, is a user defined value for
setting the percentage of the corner current.
NOTE HD4070
®
:
Proper mult-drop operation requires a Rev C or higher Breakout board in the
HD4070
®
as well as Rev K or higher control software in the HD4070
®
.
Содержание Edge TI
Страница 24: ...Table of Contents XXII...
Страница 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Страница 54: ...Overview 30...
Страница 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Страница 88: ...Setups 64...
Страница 102: ...Shape Manager 78 As new parts are added they will be displayed on the selected plate in preparation for final placement...
Страница 116: ...Shape Manager 92...
Страница 128: ...Files 104...
Страница 280: ...Part Options 256...
Страница 317: ...Diagnostics 293 DriveTop from Indramat...
Страница 335: ...Password Setups 311 The following Speeds setup parameter will be available when Tilt Rotator has been enabled...
Страница 402: ...Phoenix Link 378...
Страница 420: ...Sensor THC 396...
Страница 428: ...Command THC 404...
Страница 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Страница 470: ...Program Codes 446...
Страница 478: ...Automated Plasma Interface 454 Inputs...
Страница 479: ...Automated Plasma Interface 455 Inputs...
Страница 480: ...Automated Plasma Interface 456 Outputs...
Страница 496: ...Automated Plasma Interface 472...
Страница 520: ...MicroEdge 496...
Страница 532: ...Edge Ti 508 Optional Motor Information...
Страница 540: ...Edge Ti 516...
Страница 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Страница 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Страница 558: ...Networking 534...
Страница 561: ...Networking 537...
Страница 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Страница 572: ...Networking 548...
Страница 573: ......
Страница 574: ...Printed in the USA Rev 7 50 MANU 0053...