Duramax/Duramax Hyamp Robotic Torches
Service Manual 807460
57
4 – Component Replacement
Figure 24 – Duramax 45° (top) and Duramax Hyamp 45° (bottom)
Install the positioning barrel
1.
Lay the right half of the positioning barrel on a flat surface with the inside facing up.
If replacing the positioning barrel, use the new barrel halves included in the kit.
2.
Press the cap-sensor switch into its post hole and onto its mounting post. (See
3.
Route the cap-sensor wires below the slot for the gas hose fitting’s flange.
4.
Route the pilot arc wire under the gas tube and above the slot for the gas hose fitting’s flange. (See
and
.)
2
3
4
1
1
Cap-sensor switch mounting post
2
Cap-sensor switch post hole
3
Gas fitting flange slot
4
Strain relief slot