2 – Torch Setup
Figure 7
13.
Thread the torch body into the torch lead until snug.
The white wires of the lead should be facing up.
14.
Use 2 wrenches to tighten the gas fitting that secures the torch body to the torch lead to 69.1 kg∙cm
(60 inch∙pounds).
15.
Route the pilot arc wire under the gas tube and above the slot for the gas hose fitting’s flange. See
and
.
16.
Tighten the pilot terminal screw to 17.3 kg∙cm (15 inch∙pounds).
The wire should go slightly down into the positioning barrel.
17.
Press the cap-sensor switch into its post hole and onto its mounting post. (See
.)
18.
Route the cap-sensor wires below the slot for the gas hose fitting’s flange.
Conical surface of the gas tube
fitting