Industrial
LED Linear High Bay Lights
(WILL Series)
Features
• UL&CUL No E490237
Suitable for damp location
• IP40 Rated Ingress Protection
BEFORE YOU INSTALL
Read these instructions completely and carefully.
ATTENTION
WARNING/ADVERTISEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
• Follow all NEC and local codes.
• Use only UL or IEC approved wire for input/output connections.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Electrical Requirements
The LED driver must be supplied with 100-277
VAC, 50/60 Hz per product label and connected
to an individual properly grounded branch circuit,
protected by a 15 or 20 ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system
shall be done in accordance with National Electric
Code (NEC) Article 600 and local codes.
Prepare Electrical Wiring
1.Please connect the input wire in correct way,
white wire is N, black wire is L, green wire is
ground connection. Pls also make sure the
wire connection is fixed perfectly before using.
Announcements:
1.This equipment is only a professional installation. Non-professional personnel shall not remove or install the
equipment.
2.Please read the instruction manual before installation and keep it for future reference.
3.To avoid damage, falling, electric shock or fire, please do not modify the lamp or replace accessories without
confirming with the supplier
4.Maintenance/installation and replacement the lamps, please confirm to cut off the power supply, and the lamps
have set up a cooling. Please make sure the lamps have been properly installed before processing power.
5.Ensure the accurate and reliable connection.
6.Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when using.
P5
P4
EMERGENCY
LED
DRIVER
- The LED Emergency Equipment for led product with external
driver allows the same LED fixture to be used for both normal
and emergency operation.
- In the event of a power failure, the LED Emergency Equipment
switches to the emergency mode and operates the existing
fixture for over 90 minutes.
- The unit contains a battery, charger and converter circuit in a
single can and is available in different mounting configurations
for individual fixture requirements.
EMERGENCY
LEDRIVER
UL Listed
For field or factory installation
Universal Input Voltage
100 277VAC 50 60Hz
AC Input Current
90mA max.
AC Input Power Rating
6.0W max.
Output Current and Voltage
420-800mA 25V 48V
Output Power
20W max.
Illumination Time
90 Minutes
Full Warranty
5 Years
Test Switch Charging Indicator Light
Low Voltage,illuminated Test Switch
Battery
High-Temperature, Ni-MH battery
Battery Charging Current
250mA
Recharge Time
24Hours
Temperature Rating
0°C to 50°C (32°F to 122°F)
LED Luminaire