background image

 

3

Press 

DOWN

 to 

SAFETY TIMER

 - Adjustable between 20 and 300 minutes.  An alarm will sound during charging after selected 

time interval during charging has elapsed. Set the time for about 30% longer than it should take your pack to charge.   
Keep in mind that a badly balanced pack may take longer than normal to charge, so don’t set this too tight.  A Lipo pack at 1C 
rate might take as much as 120 minutes to charge, so timer of about 160~180 minutes may be appropriate.  Note that while 
other safety checks based on capacity and voltage are also working for you, charging should never be left unattended in any 
case. 
 
Press 

DOWN

 to 

TCS CAPACITY

 – For LiPo and LiIon battery types Terminal Capacity Selection is available from 50% to 100% of 

pack capacity.  During the charge, the EOS 0610i DUOII will continually estimate capacity in the pack, and either terminate the 
charge or sound a signal tone (and continue charging) when your selected TCS percentage is reached, depending on the value 
for you set for 

TCS END ACTION

.   See end of manual for more details on TCS. 

 
Press 

DOWN

 to 

TCS END ACTION

 – Values are CONTINUE and STOP.  CONTINUE is the default.  In this case, when TCS% is 

reached for settings 50% to 95%, the charger will “beep” 10 times, but continue charging to 100% until stopped.  If TCS 
ACTION is set to STOP, the charger will stop charging at that TCS setting and - if balancing is complete – then give COMPLETE 
(END) Buzzer according to you buzzer settings.  (or continue till balanced, then give End buzzer).    
 

Press 

DOWN

 to 

DSCH CURRENT  

– 

If you’ll be discharging, you’ll set the discharge current here. Note that depending on the voltage of the 

pack, the current you set may not be obtainable if the total  Volts multiplied by Current (A) exceeds 50W.

 

 

Press 

DOWN

 to 

DSCH VOLTAGE 

per cell

  

– 

Lithium types should only be discharged for storage, so we recommend that you use STORE 

MODE for that. Otherwise, you need to be sure of the  V/cell setting yourself, according to your battery type.  Over-discharge can damage packs.

 

 
Pressing 

DOWN

 for a last time returns you to the ‘Memory Select’ screen. 

 
At this point, see flowchart 

(7) LiIo / LiPo / A123 BATTERY START

.  Holding the 

ENTER

 key pressed down for two seconds 

or more will start the CHARGE, STORE, or DISCHARGE process (select with UP/DOWN Keys) for LiPo, LiIon, and A123 types, no 
matter where in the MEMORY (CHARGE) screens you may be.  Additionally- if balancer circuit is connected – SYNC MODE is 
available via ENTER (short push) and UP/DOWN arrow keys. 
 
With “CHARGE START SOLO MODE” selected, hold down 

ENTER 

for 2 seconds. Hold down 

ENTER

 again, the charger will then 

read **BATTERY CHECK** and then ask you to confirm the number of cells in your battery pack. Press 

ENTER

 (short press) for 

a final time to start charging. (if balancer is connected, a 10-second countdown occurs, then auto start). 
 

Note:

  If the Lithium-based pack is NOT connected to the balancer port, the Charger will read NO BALANCER. We strongly 

recommend using the balancer at ALL times.   
 
Holding down 

ENTER

 (2 seconds) at any time while charging a battery will then 

STOP

 charging (or discharging, etc…). 

 

 

MODE SELECTIONS 

 
Before

 Charging/Discharging/Store are in progress, Pressing the MODE button will scroll you through the MEMORY, DATA VIEW, 

BALANCER and USER SETUP screens, allowing you to change parameters as you like (see charts for each)

 

 
During

 Charging/Discharging/Store , Pressing the MODE button will scroll you through the MEMORY, BALANCER and QUICK 

VIEW Data screens. (see chart 

(9) OPERATION and FINISH DISPLAY

 
* MEMORY – Short-press 

UP

/

DOWN 

buttons to scroll through the data presented. At the top memory screen (showing C: A), 

you can press 

ENTER

 and 

UP

/

DOWN

 to change charge current if desired. You can also LONG-press (2-seconds) 

UP

 button to 

see each screen presented in turn at two-second intervals. 
 
* BALANCER – 

UP

/

DOWN

 buttons to see detailed information on cell balancing, and individual cell voltages 

 
* QUICK VIEW – Shows the following useful info on a single screen: 
    CAPACITY mAh/Ah (Charged in “C” or Discharged out “D”) 
    INPUT VOLTAGE (Vi) 
    PACK VOLTAGE (V) 
    CHARGE CURRENT (A) 
    CAPACITY (%) of the pack at current time. 

 

---- DATA VIEW

 

Press the 

MODE

 button until you reach the 

DATA VIEW

 screen. (see chart (3) Data View Display) 

Use the 

UP

 or 

DOWN

 key to scroll through the various information presented:  

 
*

INPUT

 – Current input voltage from the power supply 

*

OUTPUT

 – The output voltage of charger while charging, or pack voltage of the battery while connected but not charging 

*

BAT. RES

 – The internal resistance (IR) of the battery pack in m

                   (IR value appears some seconds after charge is started, and will become more accurate as charge progresses) 
*

TEMP

 and 

PEAK TEMP

 – Current Temp, and Peak Temp recorded during the charge (requires optional temp sensor) 

*

CHARGE TIME, CHARGE CURRENT

 

*

PEAK CHARGE VOLTAGE 

(see chart for other information screens available under Data View)

 

Отзывы: