Displays during Charge, Discharge, and Cycle
Note that exact display may depend on type of battery and connection. For example, Lithium types when connected to a
balancer will alternately show CHG / BLC at top left while charging, and CHG / BLC / END when finished charging. Also note
that after charging the EOS0606i may apply maintenance trickle charge or balance discharge as needed until disconnected.
Completion Display
When the Enter button is pressed, charge or discharge will be stopped.
In order to move back to the main display, press the Enter button.
Data Display – Keys
Press BATT TYPE during charging or discharging to view the data display menu.
Use INC and DEC to scroll through the data screens.
Pressing BATT TYPE again will return you to the charge/discharge screen.
Data Display – Screens
(Example: During a Balancer-Connected Lithium Charge)
-------------- NOTE: Balancing without Charging for LIPO and LiFePO4 (A123) Type Packs ----------------
If you have a Lipo or LiFePO4 type pack, and simply want to balance the cells without charging the pack, you only need to set
the proper Battery Type first (just as if you were going to charge), then connect the battery to charger via main input leads
and balance adapter. The 0606i will check the voltage of each cell. If the pack is NOT already over-discharged, it will then
start discharging the cells with the highest voltage. As soon as all the cells in the pack are within balancing tolerance – or if
any one cell should reach the acceptable voltage lower limit for that cell type - the charger will stop balancing the pack.
CHG 030:25 00000
NC + 3.00A 10 .75V
DCH 030:25 00000
NC - 3.00A 10 .750V
END 030:00 00000
NC 100mA 10.75V
INPUT = 12.00V
OUTPUT = 23.50V
DELAY TIME
5 : 00
CHG: charge
DCH: discharge
C
→
D: cycle
D
→
C: cycle
NC: NiCd
NM: NiMH
LP: LiPo
LF: A123/LiFe
Pb: Lead-Acid
INPUT = 12.00V
OUTPUT = 23.50V
3.92 3.92 3.92V
3.92 3.91 3.93V
LCB-MAX =3.937V
LCB-MIN =3.923V
DEC
INC
LCB-[01] =3.923V
LCB-[AVG =3.930V
ChgCAPA= 400mAh
DchCAPA = 0mAh
CHG PEAK= 23.62V
DCHG AVR = 0.00V
Time in minutes : sec
Capacity in mAh
Time Delay in minutes between
Charging and Discharging or
Discharging and Charging
DEC
INC
DEC
INC
DEC
INC
DEC
INC
ENTER
ENTER
CHG 15:00 00500
LP + 2.20A 22.200V
CHG 0:00 00000
LP + 2.20A 22.200V