Pb CHARGE
C=4.0A 12Vpack
Pb CHARGE
C=6.0A 12Vpack
Pb DISCHARGE
D=1.00A 12Vpack
Setting charge current
Adjust and find the desired charge current which ranges from 0.1A to 6.0A with INC & DEC
buttons. Press the ENTER button to confirm setting.
Setting discharge current
Adjust and find the desired discharge current, ranging from 0.1A to 1A, with INC & DEC buttons.
Press the ENTER button to confirm setting. The 5W max may reduce the current you set
depending on the voltage of your battery pack.
Setting discharge cutoff voltage
This is the voltage that the charger should stop discharging the battery.
Adjust and find total discharge cutoff voltages to be discharged from 0.1V to 16.8V with INC &
DEC buttons. Press the ENTER button to confirm setting.
Setting cycle
This is to set cycling with two options ( Charge to Discharge / Discharge to Charge). Set cycling
with INC & DEC buttons, and press the ENTER button to confirm setting.
Setting Delta-V and Trickle Options for NiCd/NiMH
(NiMH mode is the same as below, except Mode shows ‘NiMH’)
Delta-V Defaults (and minimum values) are: NiCd 5mV/cell, NiMH 3mV/cell. In most cases these should be left alone.
Advanced users may wish to increase settings to archive a delayed charge termination, but if set to high can result in over-
charge and could be dangerous.
Trickle charge maintains a NiCd/NiMH battery charge until the battery is removed. Trickle rate depends on charge current
setting and ranges from 50mA to 200mA. If charge current is <1A, there is no trickle. You can turn trickle such that it is
always OFF, as shown above.
Pb MODE
(lead-acid battery)
Setting charge current
Adjust and find the desired charge current which ranges from 0.1A to 6.0A with INC & DEC buttons.
Press the ENTER button to confirm setting
Setting total battery voltage for Lead-Acid Battery
Select the proper total battery voltage to be charged or discharged with INC & DEC buttons – 2V, 4V,
6V, 8V, 10V, and 12V [2V per cell types only]
Setting discharge current
Adjust and find the desired discharge current from 0.10A to 1.00A (0.01A per step) with INC & DEC
button. Press the ENTER button to confirm setting.
Pb CHARGE
C=4.0A 12Vpack
DEC
INC
Pb DISCHARGE
D=1.00A 12Vpack
BATT TYPE
Pb CHARGE
C=4.0A 12Vpack
Pb CHARGE
C=4.0A 12Vpack
BATTERY CHECK
WAIT PLEASE. . . .
CHG 0:00 00000
Pb + 4.0A 12.000V
Pb DISCHARGE
D=1.00A 12Vpack
Pb DISCHARGE
D=1.00A 12Vpack
BATTERY CHECK
WAIT PLEASE. . . .
CHG 0:00 00000
Pb - 1.0A 12.000V
ENTER
ENTER
NiCd CHARGE
C=3.00A 16.8V
NiCd DISCHARGE
D=1.00A 16.8V
NiCd DISCHARGE
D=1.00A 16.8V
NiCd CYCLE C->D 5
C=3.0A D=1.00A
INC
INC
INC
INC
DEC
DEC
DEC
DEC
ENTER
ENTER
START
START
NiCd CHARGE
C=3.0A
NiCd DISCHARGE
D=0.50A 4.8 V
NiCd CYCLE D->C 5
C=3.0A D=0.50A
INC
INC
DEC
DEC
INC
DEC
NiCd delta-peak-
volt = 5mV/cell
INC
DEC
NiCd Trickle
Charge = ON
NiCd Trickle
Charge = OFF
ENTER
INC
DEC