background image

IN-tact™ 1202 IP Gateway

The Hypercom

®

 IN-

tact

 1202 is an IP gateway device that provides protocol 

conversion and secure managed connections for a dial Point of Sale (POS) 
terminal. The product is used to convert transactions to Internet Protocol (IP) 
transactions over Ethernet UTP. The IN-

tact

 1202 allows you to use your current 

POS dial terminal and take advantage of a DSL, cable modem, or VPN Ethernet 
connection to access a host interface using TCP/IP protocol.

The unit is easy to install and has been pre-configured with all needed 
information. The only action required on your part is to connect the network and 
power cables. These installation instructions are provided to help you make the 
necessary connections. 

Compliance

This equipment has been tested and is compliant with:

• FCC Part 15 (ICES-003)

• UL 60950-1 (CSA C.22 No. 60950-1)

See the 

IN-tact 1202 Hardware Guide

 for complete US and International 

compliance statements.

Safety Precautions

This section describes the precautions necessary to install Hypercom products 
safely and reliably.

General:

 The IN-

tact

 1202 is considered to be Safety Class III equipment that 

requires connection to an earth-ground terminal. As such, an uninterrupted safety 
ground must be provided from the earthed AC main supply socket-outlet to which 
the IN-

tact

 1202 is connected. The socket-outlet providing AC power to the 

equipment must be installed near the equipment and be easily accessible. If it is 
suspected that this earthing protection is impaired, turn the equipment off, secure 
it against any unintended operation, and schedule the repair of the equipment.

Electrical Safety:

 Observe all proper electrical safety practices when operating 

any equipment attached to an active power source.

Equipment Damage:

 Ensure that the correct adapters, interfaces, or cables 

are installed in the IN-

tact

 1202 ports. Otherwise, equipment damage may 

occur.

Interconnectivity:

 Unless otherwise specified, the interfaces of the IN-

tact

 

1202 are not intended to directly connect to off-premise wiring.

Ventilation:

 Allow proper clearance for ventilation. Inadequate ventilation may 

affect operation.

Fuse/Battery Replacement:

 There are no user-serviceable fuses or batteries 

within the IN-

tact

 1202 unit.

Unpack/Check Contents 

After unpacking the IN-

tact

 1202, verify that you have the following parts:

IN-

tact

 1202 unit (P/N 010304-003)

Power adapter (P/N 870003-001)

You can find the IN-

tact

 documentation on the Hypercom Web site at 

www.hypercom.com. Look under Products and select 

Related Information

 > 

Manuals 

IN-tact Series

.

Mounting Instructions

The IN-

tact

 1202 may be placed on a shelf, countertop, or other convenient 

location. Optionally, it can be mounted on a wall or under a countertop. Perform 
all mounting before connecting any cables. A mounting template and 
instructions are on the back page of this document. 

Connection Points

Ethernet Port

RS-232 Port

Standard RJ-11

connector to

Power

 dial terminal

Connect the Power Supply

1.

Connect the three prong connector of the power supply cord to the power 
port on the back of the IN-

tact

 1202 unit (shown above).

2.

Connect the standard AC power plug to an approved power outlet or surge 
protector. The unit powers on upon connection; there is no power switch. 

Check the LEDs

1.

After connecting the IN-

tact

 1202 unit, check the power LED on the front 

panel. It should now be glowing green, indicating that the unit is powered on. 

2.

If power is on, check the LEDs at the bottom of the LAN connection on the 
back panel. They should both be flashing, indicating that the unit is 
communicating with the router or other network device and seeking a DHCP 
IP address. Once an address is acquired, the green LED lights solid and 
flashes whenever LAN communication traffic is detected. The yellow LED is 
normally off and flashes whenever communication traffic to the IN-

tact

 

occurs.

Отзывы: