15
PERIODIC MAINTENANCE 2-5-1
AIR CLEANER
If the air cleaner is clogged with dust, intake
resistance will be increased, with a resultant
decrease in power output and an increase in fuel
consumption.
Check and clean the air cleaner element in the
following manner :
■
■
●
Remove the seat and right side cover.
●
Remove the six screws
①
and remove the air
cleaner case cover.
●
Take off the air cleaner element
②
.
Clean the air cleaner element for the follwing :
●
Fill a washing pan of a proper size with a non-
flammable cleaning solvent
. Immerse the air
cleaner element in the cleaning solvent and wash
it.
●
Gently squeeze the air cleaner element between
the palms of both hands to remove the excess
solvent : do not twist or wring the element or it will
develop tears.
●
Immerse the element in HYOSUNG genuine oil
, and then squeeze out the excess oil leaving
the element slightly wet.
●
Reinstall the cleaned or new air cleaner element
in the reverse order of removal.
Clean Every 3,000 km,
Replace Every 12,000 km.
①
②
Inspect Interval