Chapter4. System Installation Installation Manual
4-6
©
Hyosung TNS, Inc.
All Rights Reserved.
Power Requirements
► The power for the site
▪ 100~127Vac (±10%), Max 12A at 50/60(±3)Hz, Single-phase
Note 1
: Dedicated 20A Service
‐
The HYOSUNG MX8300D/8300T ATM must have a dedicated 20A
service.
► Power Consumption
▪ Idle (Min)
HEATER OFF: 204W
HEATER ON: 496W
▪ Transaction (Max)
HEATER OFF: 346W
HEATER ON: 610W
► Thermal Output
▪ Idle (Min)
HEATER OFF: 696.1 BTU/hr
HEATER ON: 1692.4 BTU/hr
▪ Transaction (Max)
HEATER OFF: 1180.6 BTU/hr
HEATER ON: 2081.4 BTU/hr
The power use depends on the number and type of devices present in the recycler/dispenser
and the type of transaction the recycler/dispenser is performing.