Hylio Agrodrone (AG-110) Maintenance Manual
©2020 Hylio Inc. All Rights Reserved
3
Daily Maintenance Checklist
Follow these steps for all UAS at the end of each day of spray operation. All cleaning MUST be
completed same day to ensure hardware longevity.
STEP 1:
CLEANING
1
Clean chemical residue from the inside of the tank and pump system:
Pump 1 Gal clean water through the system 3 times
Use a degreaser if necessary
2
Clean chemical waste and dirt off drone exterior with a wet rag
(a degreaser is recommended to be used)
A. Tank
B. Frame
C. Motors
D. Radars
E. Propellers
F. Pump, flowmeter, and spray bars
3
Remove nozzle tips and nozzle filters from spray bars, soak in water and clean
STEP 2:
HARDWARE MAINTENANCE
4
Tighten screws on carbon fiber extension bar mounting plates
5
Inspect GPS bases, Radar mounts, motors, drone base, extension bar/base, and
propellers for damage, looseness, or missing screws. If you cannot resolve a problem
on your own, contact the Hylio team immediately for assistance
6
Check for leaks in spray system
7
Verify that the propellers are secured tightly and undamaged
8
Verify that all hardware is tightly secured and clean
STEP 3:
AGROSOL
9
Connect the drone to AgroSol and go to the maintenance tab
10 Download logs
11 Upload logs
12 Clear logs
13
Perform the compass calibration (Every 3 months, if drone begins to fly poorly, if drone
is moved more than 50 miles, or drone is near an area of significant magnetic
interference). Do not calibrate near large metal objects: buildings, vehicles, power lines
STEP 4:
TOOL-KIT
14
Check spray team’s Tool-Kit for any broken or missing parts