Hyking HK-GIR8362 Скачать руководство пользователя страница 4

 

 

IMPORTANT SAFEGUARDS 

1. Read these instructions before attempting installation or operation of dome device.  

2. Keep these instructions for future reference. 

3. Heed all warnings and adhere to electrical specifications. Follow all instructions.  

4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners.  

5. Should the  lens of  the camera become dirty,  use special  lens  cleaning cloth and solution to 
properly clean it. 

6. Do not block any ventilation openings. Install in acc

ordance with manufacturer’s instructions. 

7. Use only attachments or accessories specified by the manufacturer.  

8. Verify that the surface you are planning to use for attaching the dome can adequately support 
the weight of the device and mounting hardware. 

9. Protect this device against lighting storms with proper power supplies.  

10. Refer all servicing to qualified service personnel. Servicing is required when the device has 
been damaged in any  way,  when liquid traces are present, or  the presence of  loose  objects is 
evident or if  the device does  not function properly, or  has received sever impact or  has been 
dropped accidentally. 

11.  Indoor dome is for indoor use only and not suitable for outdoor or  high  humidity  locations. 
Do  not  use  this  product  under  circumstances  exceeding  specified  temperature  and  humidity 
ratings. 

12. Avoid pointing the camera directly to the sun or other extremely bright objects for prolonged 
period of time avoiding the risk of permanent damages to the imaging sensor. 

13.  The  attached  instructions  are  for  use  by  qualified  personnel  only.  To  reduce  the  risks  of 
electric shock, do  not perform any servicing other than contained in  the operating instructions 
unless you are qualified to do so. 

14. During  usage,  user should abide by all electrical safety standards and adhere  to electrical 
specifications for the operation of  the dome.  The control cable for  RS485 communications as 
well as the video signal cables should be isolated from high voltage equipment and high voltage 
cables. 

15. Use supplied power supply transformer only.

Содержание HK-GIR8362

Страница 1: ......

Страница 2: ...flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnit...

Страница 3: ...or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera 5 All electrical connections to the dome...

Страница 4: ...amaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 1...

Страница 5: ...imensions 8 2 2 1 Wall Mounted Bracket 8 2 2 2 Corner Mounted Bracket 9 2 2 3 Pole Mounted Bracket 9 2 2 4 Ceiling Mounted 10 2 3 Installation of Brackets 10 2 3 1 Wall Mounted 10 2 3 2 Corner Mounted...

Страница 6: ...Appendix Clean Transparent Cover 28 Appendix Common Knowledge on RS 485 Bus 29 1 Basic Feature of RS 485bus 29 2 Mode of Connection and Terminal Resistance 29 Appendix Address Code Mapping Table 29 A...

Страница 7: ...1 1 Product Introduction 1 1 Package Contents IR speed dome 1pc Wall mount bracket 1pc Power supply 1pc Screws kits 1pc User manual 1pc...

Страница 8: ...ades IR Illumination On 0 25 grades selectable IR Output Power 1 9 grades selectable IR Standby Power 1 9 grades selectable A B Scan User programmable A B Scan Speed 1 9 speed setting available 360 Sc...

Страница 9: ...Location Support DH SD1 OSD Menu Multiple Language Time Scheduling Function 8 tasks Alarm 4 inputs and 2 outputs Optional Timing Run Built in high precision RTC clock support time management Operating...

Страница 10: ...h group can be edited independently Optional IP module built in provision Built in high density RTC clock supports time management function Optional alarm 4 alarm inputs and 2 alarm outputs Park actio...

Страница 11: ...scan the camera turning to up down left and right and zooming in or out can be saved This function remembers and imitates a process of operator s operation This dome camera has 4 path patterns Each p...

Страница 12: ...t the speed will become faster 360 Scan Dome 360 clockwise continuously scans the display scene at set speed in horizontal direction under the condition that pitch angle remains the same In the scanni...

Страница 13: ...Settings DIP switch SW1 is the address settings of camera It is a 8 bit switch Each switch corresponds with 0 or 1 in the Binary code OFF status means 0 while ON status means 1 See illustration above...

Страница 14: ...nication signal and other signals the parallel matching resistor is needed in the communication interface of dome camera at the end away from the control center DIP switch SW2 has a control switch of...

Страница 15: ...9 2 2 2 Corner Mounted Bracket 2 2 3 Pole Mounted Bracket...

Страница 16: ...e hard wall structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment The wall can bear at least 4 times the weight of the dome Install wall hanging bracke...

Страница 17: ...nted Fig 4 Installation conditions Corner mounted dome can be used in the hard wall structure with an angle of 90 whose thickness should be enough to install expansion bolt in indoor and outdoor envir...

Страница 18: ...to install expansion bolt Fig 5 b As shown in fig 6 use M8 screw nut to fix the base of corner mounted on the wall with all cables through the center holes of the corner mounted marine glue and brack...

Страница 19: ...the installation size of stainless hose clamps Factory default is 6 inches stainless hose clamps fit 130 152mm pillar The pole structure can bear at least 4 times the weight of the dome Install corner...

Страница 20: ...14 Fig 9 b As shown in fig 10 fix the wall hanging bracket with all cables through it on the pole mounted attachment Fig 10 2 3 4 Ceiling Mounted Fig 11...

Страница 21: ...3 at first unscrew the M4 screw at the side of the base of ceiling and split the base of ceiling and boom Then make the three groups of cables of power video control and alarming into the side recessi...

Страница 22: ...read at the upper end of boom tighten the boom on the base of ceiling Use the silica gel around the joint sleeve and connector of the boom to be sure water proof 2 4 Connection Connection of RS485 Bef...

Страница 23: ...ialization of pan tilt motor completes It is initializing the camera and detecting the module of camera Power on self testing completes IR SPEED DOME PROTOCOL PELCO D P COMM 2400 N 8 1 DOME ID 001 MOD...

Страница 24: ...ase the image brightness Press IRIS to enlarge the iris and increase the image brightness Preset Point Setting preset press button preset number enter Calling preset press button call number enter Del...

Страница 25: ...Left Return to main menu or cancel Zoom Display x XXX XXX is the present zoom of camera Time Display XXXX year XX month XX day XX hour XX minute XX second Angle Display XXX XX pan XXX XX tilt IR Disp...

Страница 26: ...20 4 OSD Menu...

Страница 27: ...ID When alter target ID soft protocol and baud rate please make check ID in line with the device ID at first otherwise altering can t be completed TARGET ID Target ID can be changed and edited on lin...

Страница 28: ...Call the guard tour ID edited successfully GUARD TOUR ID The tour sequence of guard tour group Its range is 1 16 POINT The preset of guard tour Its range is 01 64 settable TIME The default time of al...

Страница 29: ...ion 2 Press the up and down keys in the keyboard to edit the mask number as 1 which is entered by pressing the right key means selecting this mode while hourglass symbol means editing this mode 3 Move...

Страница 30: ...monitoring comes true 4 2 7 Alarm ALARM IN Alarm input has OFF and ON selectable ALARM OUT Alarm output has NC an NO selectable DWELL TIME Its range is 05 10S ALARM 1 No action and preset 1 16 are sel...

Страница 31: ...table 4 3 2 CAM AE AE MODE It has auto and manual selectable IRIS MODE It has auto and manual selectable IRIS TIME Set the speed of iris varying SHUTTER Set the camera shutter There are auto and manua...

Страница 32: ...dule 01 20 Default setting is 15 Eg when the zoom value is set to 06 the IR LEDs will automatically switch from near illumination to far illumination after the zoom value reaches to 6X or more than 6X...

Страница 33: ...is completed it will respond other schedules Please make sure there is only one schedule at some certain period System will return to preset 1 after completing schedule 4 7 Language LANGUAGE Language...

Страница 34: ...voltage substations measure of installation of additional high power lightning protection equipment and lightning rod must be taken Lightning protection and grounding of outdoor devices and lines must...

Страница 35: ...nd Terminal Resistance 2 1 Industry standard of RS485 bus requires that connection mode in a daisy chain should be used between the devices with 120 terminal resistances connected at the both ends As...

Страница 36: ...0 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF O...

Страница 37: ...OFF OFF ON OFF OFF OFF OFF 11 OFF ON OFF ON OFF OFF OFF OFF 12 ON ON OFF ON OFF OFF OFF OFF 13 OFF OFF ON ON OFF OFF OFF OFF 14 ON OFF ON ON OFF OFF OFF OFF 15 OFF ON ON ON OFF OFF OFF OFF 16 ON ON O...

Страница 38: ...32 Appendix Exception Handling 255 OFF ON ON ON ON ON ON ON 256 ON ON ON ON ON ON ON ON Issue Possible Reason Solution...

Страница 39: ...ble polarity Verify the polarity of the RS485 connection as per the instruction manual Noise after self testing Mechanical obstruction Verify and correct it Camera module is not installed correct Corr...

Страница 40: ...this manual without notice The content of manual is offered according to the current state Unless applicable law otherwise specified the company does not make any kind of clear or tacit reassurance a...

Страница 41: ...35...

Отзывы: