7
User can set the function or parameter, or check the related information through the OSD.
2 Installation
2.1 DIP Switch Settings
2.1.1 Preparation
Before installation, make sure that the protocol, baud rate and address code used by the
product is fully consistent with the control system. Corresponding DIP switch site can be seen
below:
2.1.2 Address Settings
DIP switch SW1 is the address settings of camera. It is a 8 -bit switch. Each switch corresponds
with 0 or 1 in the Binary code. OFF status means 0 while ON status means 1.
(See illustration above) Turn on the 1st and 3rd (allocated to ON position) and get the binary
code 00000101, so the correspondence address is 5.
Detailed settings please refer to Appendix
Ⅳ
“Address Code Mapping Table”.
2.1.3 Baud Rate Settings
The 4th
and 5th DIP Switches set the Baud rate. Factory-default setting is 2400bps.
Baud rate: 1200bps, 2400bps, 4800bps, 9600bps selectable