It is essential to consider the diameter of the recirculation pipe in relation to the time required for complete
recirculation. We must instal the number of chambers required in order that all pool-water will pass through the
chambers, and so that the circulation flow shall not fall below <10%, as a by-pass and in parallel. For example,
we recommend using PVC pipes:
Pipe
≤
75 mm
1 chamber or 2, in line
Pipe 90 to 140 mm
minimum 2 chambers in parallel
Pipe 140
≤
225 mm
minimum 3 chambers in parallel
Pipe 225
≤
300 mm
minimum 4 chambers in parallel
* The material of the chamber is compatible with any PVC glue
Examples of installations
Serial
Parallel
IN
Water entrance
-
Titane electrodes holder
-
Sensors (temperature, pH,
Redox)
OUT
Water exit
-
Copper electrodes holder
-
pH injector
-
Peroxide injector
-
Chlorine injector
(depending on the models)
Correct Instalation