10 Fault Finding
10 Fault Finding
10.1 Fault Finding
WARNING !
The Controller sequential logic monitors and checks the
compressor status through all stages of the operational cycle. At
each stage, the configuration and parameter limits set within the
Controller must be met for continued safe operation of the
compressor.
If faults occur they appear on the Controller display with a specific
code, the last character, E, A or R, identifies the fault type.
10.2 Shutdown Trip Error (E) – Menu P03
A shutdown error stops the compressor immediately or by normal
stopping sequence, preventing damage or a hazardous condition.
The error condition must be located and corrected, press reset to
cancel the error and the compressor can restart. Immediate
shutdown error codes have a first character of 0, normal stopping
sequence records 1 as the first character.
10.3 Alarm (A) – Menu P04
Alarms occur as a warning when normal operating conditions are
exceeded, but will not stop the compressor from being started and
run. General alarm codes start with a first character of 2, service
alarms begin with 4.
A service timer counts down from set values until a routine service
is due at 0 that sets off an alarm. A negative value count
continues until the timer is reset by maintenance personnel after
the required service.
10.4 Run Inhibit (R) – Menu P05
A run inhibit will prevent motor start until the fault is located and
corrected. With normal operational status restored, press reset to
cancel the error.
Further menus with restricted access codes are intended for
service level activities 1 and 2. These are reserved for use by fully
trained Hydrovane authorised service engineers.
We strongly advise that no attempt is made to access these
structures, continued safe operation may be impaired and/or
serious damage may occur.
10.5 Fault Display Symbols
General fault
Emergency stop
Excess pressure
Power failure
Above set temperature limit
Lubrication, oil, oil level
Dewpoint
Motor
Service due, maintenance
Filter differential, filter service
Er 0010 E
Emergency stop
Er 0020 E
Fan motor overtemperature or circuit breaker
tripped
Er 0030 E
Motor overload tripped (if fitted)
Er 0080 E
Motor fault (fault relay contact, overload device
contact or thermistor)
Er 0115 E
Delivery pressure sensor fault
Er 0119 E
Delivery pressure high
Er 0125 E
Delivery temperature sensor fault
Er 0129 E
Delivery temperature high
Er 0135 E
Compressor pressure sensor fault
Er 0821 E
Low resistance, short circuit/short circuit to earth
condition, cable or sensor fault
Er 0836 E
Controller internal error
Er 0846 E
Delivery pressure sensor range set too low for
default pressure settings to be applied
Er 0d01 E
485 communication not established
Er 0d02 E
485 communication lost
Er 0d03 E
Communication error reported by VSD
Er 0d06 E
VSD error (see P00 - dE)
Er 0d08 E
Safety interlock error (VSD physical start)
Er 2118 A
Delivery pressure high
Er 2128 A
Delivery temperature high
Er 2816 A
Power failure in start mode
Er 2d07 A
Drive alarm (see P00 - dE)
Er 2d09 A
Motor overload, unloads until current reduced
Er 4804 A
Service hours time expired, service due (reset
service hours countdown timer)
Er 3123 R
RSU delivery temperature (Td) below the set
temperature run inhibit level.
Controller allows motor start when temperature
increases above the set level.
Fluid Force 2000 is set at - 5°C
Fluid Force HPO has a value of -15°C.
Er 3137 R
Run inhibited until restart time reached after
power failure.
Er 3d04 R
Drive type mismatch
Er 3d05 R
Motor type mismatch